EasyManua.ls Logo

Makita HM1202 - General Safety Rules; Electrical Safety Precautions

Makita HM1202
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Repairing
<1> Dismounting of armature
(1) Take off the rear cover from the motor housing
by loosening 2 pcs.of tapping screw M4x18.
And then take off the carbon brushes after
taking off the brush holder cap.
(2) Take off the handle and controller cover
by loosening 2 pcs.of hex socket hd.bolt M6x40
and 4 pcs.of hex socket hd.bolt M6x30.
(3) Dismount the motor housing by loosening
4 pcs.of hex socket hd.bolt M6x40.
(4) Support the machine with the repairing jig No.1R023,
1R218 and 1R022.
Put a round stick (repairing jig No.1R234 or 1R235)
on the armature
The armature can be dismounted from the
motor housing by pushing the above round stick
with arbor press.
Screwdriver
Brush Holder Cap
Tapping screw M4x18
Hex socket hd.bolt M6x40
Hex socket hd.bolt M6x30
Controller cover
Hex socket hd.bolt M6x40
Motor housing
Base of arbor press
Armature
1R022
1R023
1R218
1R234 or
1R235
Arbor press
P 2 / 14

Other manuals for Makita HM1202

Related product manuals