Do you have a question about the Malvern Nano Series and is the answer not in the manual?
Detector | Avalanche Photodiode (APD) |
---|---|
Measurement Principle | Dynamic Light Scattering (DLS) |
Temperature Range | 0°C - 90°C |
Light Source | 633 nm |
Scattering Angle | 173° (backscatter) |
Sample Volume | 12 µL - 4 mL |
Size Accuracy | ± 2% of NIST traceable standard |
Particle Size Range | 0.3 nm - 10 μm (model dependent) |
Zeta Potential Precision | Typically ±0.12 μm.cm/V.s on NIST traceable standards |
Specifies environmental conditions required for the Zetasizer Nano, including light, heat, and ventilation.
Provides essential Health and Safety information for all users of the Zetasizer Nano.
Covers general warnings and site requirements for safe operation of the instrument.
Safety warnings regarding instrument placement and ventilation.
Alerts about potentially hazardous temperatures within the cell area.
Details laser safety classifications and warnings for the Zetasizer Nano.
Provides warnings and precautions regarding the electrical safety of the instrument.
Guidelines for safe use of power cords and power supply units.
Information on using extension leads, AC adapters, and uninterruptible power supplies safely.
Covers user maintenance procedures for the Zetasizer Nano optical unit.
Comprehensive warnings and precautions for handling samples safely.
Identifies all the connections and components located on the rear panel of the instrument.
Details the cell area, its temperature control, and safety warnings.
Explains how the Malvern Zetasizer software controls measurements and processes data.
Guides on how to reconnect the Zetasizer Nano system after moving or changing the computer.
Step-by-step instructions for physically connecting the Zetasizer Nano instrument and computer.
Instructions for installing the Zetasizer software from the CD.
Steps to turn on the instrument and start the software for operation.
Guides through performing an installation test using the Zeta potential transfer standard.
Steps to run the installation test macro within the Zetasizer software.
Instructions on preparing cuvettes or cells for size and zeta potential measurements.
Detailed steps for performing the size test using a cuvette.
Detailed steps for performing the zeta potential test using a folded capillary cell.
Describes how to interpret the results of the installation test, indicating pass or fail.
Shows examples of test results indicating success or failure of the system tests.
Provides troubleshooting steps if the installation test fails.
Information on the chemical compatibility of materials in contact with samples.