3-27
E8 - State of the hoses and rubber pipes
CHECK
- Check the apparent condition of the hoses (cracking), which are subject to thermal stresses and UV; their technical characteristics may
be affected (porous spots).
WARNING ABOUT LEAKS
Hydraulic oil escaping under high pressure can penetrate the skin and cause severe injuries. Immediately consult a doctor
if anyone is injured by a high-pressure jet of oil.
If you are in any doubt about a possible leak, do not look for it with your hand; instead, check with a piece of cardboard,
while protecting your hands and body.
For safety’s sake, replace any worn hoses.
E9 - State of the cylinders (leaks, rods)
CHECK
E10 - State of the cable bundles and the cables
CHECK
E11 - Front & rear wheel reducer oil
DRAIN ī˜† REPLACE
*(Contact your dealer)