3-28
F  EVERY 2000 HOURS OF OPERATION
Perform the operations described above as well as the following operations.
F1 - Valve play (*)
CHECKREGULATE
F2 - Water pump and thermostat (*)
CHECK
F3 - Alternator and starter (*)
CHECK
F4 - Hydraulic circuit pressures (*)
CHECK
F5 - Hydraulic circuit flow rates (*)
CHECK
F6 - Hydraulic oil reservoir (*)
CLEAN
- The hydraulic reservoir is a ventilated tank fitted with a snuffler, which can become blocked or deteriorate.
- If the snuffler is defective, impurities can get into the hydraulic circuit and cause damage to the components.
- If the platform is used in a dirty environment, inspect the snuffler more often.
- Install a new snuffler on the reservoir.