22 Part Number 000015432 4/18
AUTOMATIC SHUTOFF
When the ice damper is held open by ice, the gear motor,
compressor and condenser fan de-energize. The ice
machine will remain off until the 15-minute delay period
expires and the ice damper closes.
RESTART AFTER AUTOMATIC SHUTOFF
The 15-minute delay period must be expired. The delay
period starts when the ice machine enters Automatic
Shutoff and can not be overridden.
The restart sequence is dependent on the amount of time
the ice machine has been off:
1. The ice machine was off for less than 30 minutes.
When the 15-minute delay period expires, the gear motor,
compressor and condenser fan motor energize.
2. The ice machine was off for more than 30 minutes.
The gear motor and dump valve energize to drain the
water from the evaporator and reservoir. After 45 seconds,
the dump valve de-energizes. When the reservoir fills with
water, the water sensing switch closes and the compressor
and condenser fan motor energize.
CHANGING TOGGLE SWITCH POSITION IN THE
FREEZE CYCLE
Moving the toggle switch from ICE to OFF will start a
15-minute delay period.
• Moving the toggle switch immediately to the ICE
position - The ice machine waits 15 minutes, then
starts.
• Moving the toggle switch to the ICE position after 15
minutes have elapsed - The ice machine immediately
starts.