Part Number 000009036 Rev03 6/18 13
Section 2 Installation
3. Locate and remove either the membrane material or the
plug from the ice machine.
4. Apply food grade silicone and install Y connector through
the hole in the ice machine base. Connect the clear vinyl
tubing to one side of the Y branch. The other side is for
the plug removed in step 3 or the plug provided with the
iAuCS®.
Route tubing
to this area
Insert Y
connector
with tubing
Top View
Into Base of
Ice Machine
Connect
Tubing
Install plug
provided with
iAuCS®
or
plug removed in
Step 3
Y-Connector
5. Determine the amount of tubing required in the iAuCS®
control box and cut off the excess tubing.
6. Slide the tubing on the iAuCS® pump.
Slide the tubing
on the iAuCS®
pump