Part Number: 000015431 Rev01 5/19 101
Weighing the ice is the only 100% accurate check.
However, if the ice pattern is normal and the 1/8 in.
thickness is maintained, the ice slab weights listed with the
24-Hour Ice Production Charts may be used.
4. Compare the results of step 3 with step 2. Ice
production checks that are within 10% of the
chart are considered normal. If they match closely,
determine if:
Another ice machine is required.
More storage capacity is required.
Relocating the existing equipment to lower the
load conditions is required.
Contact the local Manitowoc Distributor for information on
available options and accessories.