Section 2 Installation Instructions
Part Number 000001590 2-1
Section 2
Installation Instructions
Installation Prerequisites
• Must have open site (gravity) drain available or
purchase optional drain pump (see Water Supply and
Drain Requirements).
• Must have a grounded, polarized electrical power
supply on a dedicated electrical circuit (only
appliance on circuit). If GFCI (ground fault circuit
interrupter) is required by your local electrical code, it
must be breaker type, not outlet type (see Electrical
Service).
• Must have cold water supply line available at Ice
Machine (see Water Supply and Drain
Requirements).
• Clearance and air temperatures must be met (see
Location of Ice Machine).
• If built into a cabinet, ice machine must be removable
for yearly cleaning procedure (see Interior Cleaning
and Sanitizing in section 3).
General
Call Manitowoc Foodservice at (800) 235-9698 for the
name of a local company capable of installation and
start-up services.
Proper installation requires connection to the water
supply, a drain and a dedicated electrical circuit.
These connections are the responsibilities of the
owner/operator. Improper connections can result in
personal injury, substantial property damage and
erratic machine operation. If you are unsure of your
ability to safely connect the ice machine, consult
qualified professionals or contact Manitowoc
Foodservice.
Failure to follow these installation guidelines may
affect warranty coverage.