Part Number 000001590 Rev03 11/19 9
Installation Prerequisites
Must have open site (gravity) drain available or purchase
optional drain pump (see Water Supply and Drain
Requirements).
Must have a grounded, polarized electrical power
supply on a dedicated electrical circuit (only appliance
on circuit). If GFCI (ground fault circuit interrupter) is
required by your local electrical code, it must be breaker
type, not outlet type (see Electrical Service).
Must have cold water supply line available at Ice Machine
(see Water Supply and Drain Requirements).
Clearance and air temperatures must be met (see
Location of Ice Machine).
If built into a cabinet, ice machine must be removable
for yearly cleaning procedure (see Interior Cleaning and
Sanitizing in section 3).
Ice Machine Dimensions
Minimum Cut-Out For Built-In Installations
Height Width Depth
35” (89 cm) 15” (38 cm) 26” (65 cm)
4.5"
33.5"
14.75"
23"