EasyManua.ls Logo

Manitowoc UDF0240A

Manitowoc UDF0240A
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46 Part Number 000014797 Rev02 05/18
C. Remove the Water Pump
Remove the two thumbscrews and the water pump
cove r.
Disconnect the water pump power cord.
Loosen the screws that hold the water pump in place.
Lift the water pump and bracket assembly up and off
the screws.
D. Remove the Water Trough
Remove the screws holding the water trough to the
walls of the cabinet.
Step 7 Mix a solution of cleaner and warm water.
Depending on the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean all
parts.
Solution Type Water Mixed with
Cleaner 1 gal. (4 l) 16 oz (500 ml) cleaner
Step 8 Use ½ of the cleaner/water solution to clean
all components. The cleaner solution will foam when it
contacts lime scale and mineral deposits; once the foaming
stops use a soft bristle brush, sponge or cloth (not a wire
brush) to carefully clean the parts. Soak the parts for 5
minutes (15 – 20 minutes for heavily scaled parts). Rinse all
components with clean water.