CONTENTS
MAIN TECHNICAL DATA
DIMENSIONS
INSTALLATION CAUTION
INSTALLATION
MAINTENANCE
STORAGE AND DISPOSAL
THANK YOU FOR PURCHASING
Question and Answer IconNeed help?

Do you have a question about the Manrose Aria 250 Motor and is the answer not in the manual?

Summary

Main Technical Data

Dimensions

Before Installation Caution

Professional Installation Mandate

All fan installation and electrical work must be done by a licensed electrician according to wiring rules.

Pre-Installation Safety Guidelines

Follow all safety instructions, check specifications, and ensure room air supply for safe operation.

Important Consideration Before Installing

Installation

Electrical Work Requirements

All electrical work must be carried out by a licensed electrician in accordance with national wiring rules.

Fan Installation Steps

Check fan rotation, cut hole, secure body with fixing arms, attach ducting, and secure fascia.

Installation With LED Fascia

LED Driver and Connector Setup

Attach LED driver, plug in, feed connector through, connect to driver, and hide in ceiling cavity.

LED Component Replaceability

LED lamp and driver are replaceable by disconnecting female and male connectors.

Maintenance Cautions

Cleaning, Storage and Disposal

Cleaning Procedures

Turn off power, use a soft cloth to wipe dust. Do not open unit without electrician.

Storage Recommendations

For extended periods, store cleaned unit in a cool, dry place, preferably in original packaging.

Disposal Guidelines

Do not dispose of with household waste. Check local council for recycling advice.

Overview

This document is an installation manual for the Manrose exhaust fan, covering models MRX150, MRX200, and MRX250, including all fascia options. It provides essential information for safe installation, operation, and maintenance of the device.

Function Description

The Manrose exhaust fan is designed to extract air from a room, improving ventilation and air quality. It is suitable for various indoor applications, particularly in bathrooms, where it helps remove moisture and odors. The fan can be installed with or without an LED fascia, offering flexibility in design and additional lighting functionality. Proper installation ensures efficient air extraction, contributing to a healthier indoor environment.

Important Technical Specifications

The manual details key technical specifications for each model:

Model No.: MRX150, MRX200, MRX250

Rated Voltage: All models operate at 220-240V~50Hz.

FAN Power Input:

  • MRX150: 25W
  • MRX200: 30W
  • MRX250: 50W

Noise (dB):

  • MRX150: 38 dB
  • MRX200: 38 dB
  • MRX250: 42 dB

Duct Size:

  • MRX150: 100mm Diameter
  • MRX200: 100mm Diameter
  • MRX250: 150mm Diameter

Air Delivery:

  • MRX150: 130m³/H
  • MRX200: 175m³/H
  • MRX250: 378m³/H

Dimensions: The manual provides detailed dimensions for each model, including the fascia and cut-out sizes:

MODELS A (Fascia Width) B (Cut Out Ø) C (Depth) D (Duct Diameter)
150 Models 210mm Ø197mm 188mm Ø100mm
200 Models 272mm Ø240mm 170mm Ø100mm
250 Models 326mm Ø296mm 197mm Ø150mm

These specifications highlight the varying capacities and sizes, allowing users to select the appropriate model based on their ventilation needs and installation space.

Usage Features

The Manrose exhaust fan is designed for straightforward operation once installed. Key usage features and considerations include:

  • Ease of Installation: The manual provides step-by-step instructions for installation, including cutting the hole, securing the fan body with swing fixing arms, and attaching ducting.
  • Fascia Options: The fan supports various fascia options, including an LED fascia, which integrates lighting with ventilation. The fascia is secured using spring fasteners for a firm fit.
  • Ducting Flexibility: Ducting can be attached to the air outlet, with specific guidance on avoiding sharp bends (e.g., U-shapes, sharp 90-degree turns) to maintain efficiency. For bathroom installations, the duct should decline downwards about 10 degrees to prevent water ingress.
  • Safety Precautions: Emphasizes the importance of professional electrical installation by a licensed electrician, adherence to national wiring rules (AS/NZS3000), and ensuring adequate air supply to the room for efficient operation. Minimum installation height is 2.1 meters from the floor.
  • LED Fascia Integration: For models with an LED fascia, the LED driver is attached to the fan body, and the LED output connector is fed through the motor body. The LED lamp and driver are replaceable components, allowing for easy maintenance or upgrades.
  • Disconnection Means: A means for disconnection must be incorporated into the fixed wiring in accordance with wiring rules, typically through a double pole switch with a minimum 3mm separation on all poles.

Maintenance Features

Maintaining the Manrose exhaust fan is crucial for its longevity and efficient operation. The manual outlines several maintenance guidelines:

  • Cleaning: Before cleaning, the unit must be switched off, disconnected from the power supply, and allowed to cool down. A soft cloth should be used to wipe off dust.
  • Safety During Maintenance: Strict warnings are provided against immersing any part of the fan in water or other liquids, using petrol benzene or other chemicals for cleaning, allowing water to contact electrical parts, or immersing blades/resin parts in hot water over 60°C. The fan should never be installed in extremely hot environments.
  • Professional Repair: Any repairs or opening of the unit must be carried out by a licensed electrician using original spare parts to avoid hazards and ensure compliance with safety requirements.
  • Storage: If the fan is not used for extended periods, it should be cleaned and stored in its original packaging in a cool, dry place.
  • Disposal: Electrical products should not be disposed of with household waste. Users are advised to check with their local council for proper disposal and recycling methods to prevent hazardous substances from leaking into the environment.
  • Warranty: For aftersales requirements, users should refer to the enclosed warranty card.