Page #14 background imageLoading...
Page #14 background image
12
Figure 7-3
FINALISED CD-R DISC
LOADED
SET OK
CD-R DISC PARTIALLY
RECORDED OR EMPTY
START RECORDING
FROM DIGITAL
SOURCE
START MANUAL
RECORDING FROM
ANALOG SOURCE
CD-R DISC LOADED
LEVEL
ADJUSTABLE?
NO
YES
DIGITAL IN?
OPTICAL IN?
NO
YES
RECORDING
SUCCESSFUL?
NO
YES
NO
YES
DISPLAY:
CD R
&
OPC INFO?
YES
DISC
DETECTION &
READING?
ELECTRICAL SERVICE DIAGNOSTICS:
REPLACE CDR MODULE IF
"DERRn"
OR
"BERRn"
ERROR OCCURS
CHECK:
DISC: DIRT, SCRATCHES, DAMAGED...
NO
POWER SUPPLY VOLTAGES
ELECTRICAL SERVICE DIAGNOSTICS:
REPLACE CDR MODULE IF
"DERRn"
OR
"BERRn"
ERROR OCCURS
CHECK:
WIRING
NO
YES
DISPLAY:
CD
&
T.O.C. INFO?
SEE CD-DA DISC
FAULT FINDING
CHECK:
ELECTRICAL SERVICE DIAGNOSTICS:
REPLACE CDR MODULE IF
"DERRn"
OR
"BERRn"
ERROR OCCURS
DISPLAY BOARD (SEE FAULT FINDING GUIDE DISPLAY BOARD)
EASY JOG KNOB
I
2
C COMMUNICATION
ELECTRICAL SERVICE DIAGNOSTICS:
KEYBOARD TEST
AUDIO CONNECTIONS & CABLES
CHECK:
Q311, OPTICAL RECEIVER J301
AUDIO CONNECTIONS & CABLES
I/O BOARD
FLEX CONNECTION
+5V (pin 8 conn. JJ01)
ELECTRICAL SERVICE DIAGNOSTICS:
REPLACE CDR MODULE IF
"DERRn"
OR
"BERRn"
ERROR OCCURS
CHECK:
ELECTRICAL SERVICE DIAGNOSTICS:
REPLACE CDR MODULE IF
"DERRn"
OR
"BERRn"
ERROR OCCURS
CL 96532076_018.eps