ELECTRIC OPERATED BOILER
INSTALLATION & OPERATING MANUAL
MODELS:
m M24E18A m M24E24A m M24E32A
m M24E36A m M24E42A m M24E48A
m M36E18A m M36E24A m M36E32A
m M36E36A m M36E42A m M36E48A
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ
THE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Post instructions in a prominent location to be followed in the event the user smells
gas. This information shall be obtained by consulting the local gas supplier.
35 Garvey Street
l
Everett
l
MA
l
02149
Tel: (617) 387-4100
l
Fax: 1-800-227-2659 (Ex. MA)
l
(617) 387-4456 (MA and Overseas)
S-3112 Rev.C 08/05 E-Mail: CUSTSERV@mfii.com
l
Website: www.mfii.com
Printed in U.S.A.
An Employee Owned Company

Questions and Answers

  • U
    uhuntAug 20, 2025
    Why does my Market Forge Industries Boiler fail to build up pressure?
    • F
      Frederick OsborneAug 20, 2025
      If the Market Forge Industries Boiler fails to build up pressure, first check that the circuit breaker is on. Then, check for voltage at the terminal block. Also, check that the contactors are pulling in; if the coil's continuity is open, replace it. Verify that the current flow isn't broken at the water level control by checking for voltage at L1 and L2; replace if defective. Additionally, ensure that the current flow isn't interrupted at the pressure control or high limit control switches due to maladjustment or defect; readjust to the proper setting or replace if defective. Finally, inspect the heating elements and replace any that are defective based on a continuity check.
  • N
    Nathaniel LiAug 22, 2025
    What to do if Market Forge Industries Boiler fails to reach full operating pressure?
    • S
      Susan BakerAug 22, 2025
      If your Market Forge Industries Boiler isn't reaching full operating pressure, it could be due to several reasons. Start by replacing the pressure gauge if it reads inaccurately. If the pressure control and high limit control switches are out of adjustment, follow instructions for readjusting, or replace them if defective. Ensure the safety valve is seating properly; clean or replace it if necessary. Also, check if the contactor coils are energizing and closing the circuit to the heating elements; replace either the contactor coils or the complete contactor if found defective.
  • M
    Megan ScottAug 25, 2025
    Why does the 15 lbs safety valve on my Market Forge Industries Boiler blow off prematurely?
    • S
      schultzjenniferAug 25, 2025
      If the 15 lbs. safety valve on your Market Forge Industries Boiler blows off prematurely, the pressure might be set too high, so readjust it. Another possibility is that the pressure gauge reads incorrectly, in which case you should replace it. Mineral build-up or dirt on the seat of the valve can also cause this issue, so clean it. Lastly, a weak spring valve can be the culprit, requiring you to replace the valve.
  • A
    anitaparkerAug 26, 2025
    How to fix contactor chatter in Market Forge Industries Boiler?
    • K
      Kim BellAug 26, 2025
      If the contactor chatters in your Market Forge Industries Boiler, first check that the supply voltage matches the coil contactors. If the contactor points are dirty or worn, clean or replace the contactor. A weak coil can also cause this, so replace it with the correct voltage coil.
  • C
    Cindy PattersonAug 28, 2025
    What to do if water does not enter Market Forge Industries Boiler?
    • N
      Nicole WatsonAug 28, 2025
      If water isn't entering your Market Forge Industries Boiler, ensure the water main is turned on. Check the main fuse or circuit to make sure power is reaching the unit. If the probes are dirty, remove and clean them. If 120V is verified at the solenoid coil, but it fails to open, replace the solenoid.
  • G
    Gregory PerryAug 30, 2025
    Why does my Market Forge Industries Boiler shut down and fail to restart?
    • J
      Joseph HooverAug 30, 2025
      If the Market Forge Industries Boiler builds up pressure, shuts down, and fails to come back on, the high limit switch might be set too low, or the operating pressure control switch set too high. Follow the instructions for readjusting, or replace if defective.
  • B
    brianrichardsonSep 1, 2025
    Why is the cold water condenser not working on my Market Forge Industries Boiler?
    • J
      Julie StoutSep 1, 2025
      If the cold water condenser on your Market Forge Industries Boiler isn't functioning, ensure the main water line is turned on. If the thermostat is defective, replace it. Also, tighten the coil nut and check the solenoid coil for continuity; replace it if it's open.
  • S
    swilsonSep 3, 2025
    Why does the water level fluctuate in my Market Forge Industries Boiler?
    • K
      Kevin MasonSep 3, 2025
      If the water level in the gauge glass of your Market Forge Industries Boiler fluctuates up and down, the top shut off on the water gauge might be closed. Open it.
  • D
    Daniel WilliamsSep 5, 2025
    Why does water enter Market Forge Industries Boiler so slowly?
    • C
      careydanielleSep 5, 2025
      If water enters the Market Forge Industries boiler very slowly, the strainer screen in the solenoid valve might be dirty. Clean or replace the strainer screen.
  • C
    Colleen DeleonSep 7, 2025
    How to fix a leaking air vent on Market Forge Industries Boiler?
    • J
      Jeffrey MichaelSep 7, 2025
      If the air vent on your Market Forge Industries Boiler is leaking, replace it.

Market Forge Industries M24E18A Specifications

General IconGeneral
ModelM24E18A
CategoryBoiler
ManufacturerMarket Forge Industries
Fuel TypeElectric
Heating Capacity18 KW
TypeBoiler
Voltage208/240 V