ELECTRIC OPERATED BOILER
INSTALLATION, OPERATING, MAINTENANCE AND PARTS MANUAL
MODELS:
M24E24A M24E32A M24E36A
M24E42A M24E48A M36E24A
M36E24A M36E32A M36E36A
M36E42A M36E48A
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OP-
ERATION AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING
OR SERVICING THIS EQUIPMENT.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN
THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
POST INSTRUCTIONS IN A PROMINENT LOCATION TO BE FOLLOWED IN THE EVENT
THE USER SMELLS GAS. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING
THE LOCAL GAS SUPPLIER.
Printed in U.S.A.
Form No S-3112 Rev. D
35 Garvey Street, Everett, MA 02149
Tel: (617) 387-4100, (866) 698-3188, Fax: (617) 387-4456, (800) 227-2659
custserv@mi.com, www.mi.com

Other manuals for Market Forge Industries M24E24A

Questions and Answers

  • L
    Lance WoodsAug 19, 2025
    Why does my Market Forge Industries Boiler fail to build up pressure?
    • R
      Ryan JohnsonAug 20, 2025
      If the Market Forge Industries Boiler fails to build up pressure, first check that the circuit breaker is on. Then, check for voltage at the terminal block. Also, check that the contactors are pulling in; if the coil's continuity is open, replace it. Verify that the current flow isn't broken at the water level control by checking for voltage at L1 and L2; replace if defective. Additionally, ensure that the current flow isn't interrupted at the pressure control or high limit control switches due to maladjustment or defect; readjust to the proper setting or replace if defective. Finally, inspect the heating elements and replace any that are defective based on a continuity check.
  • J
    James RuizAug 22, 2025
    What to do if Market Forge Industries Boiler fails to reach full operating pressure?
    • S
      Stacey CampbellAug 22, 2025
      If your Market Forge Industries Boiler isn't reaching full operating pressure, it could be due to several reasons. Start by replacing the pressure gauge if it reads inaccurately. If the pressure control and high limit control switches are out of adjustment, follow instructions for readjusting, or replace them if defective. Ensure the safety valve is seating properly; clean or replace it if necessary. Also, check if the contactor coils are energizing and closing the circuit to the heating elements; replace either the contactor coils or the complete contactor if found defective.
  • J
    Julia LarsonAug 25, 2025
    Why does the 15 lbs safety valve on my Market Forge Industries Boiler blow off prematurely?
    • T
      Theresa JohnsonAug 25, 2025
      If the 15 lbs. safety valve on your Market Forge Industries Boiler blows off prematurely, the pressure might be set too high, so readjust it. Another possibility is that the pressure gauge reads incorrectly, in which case you should replace it. Mineral build-up or dirt on the seat of the valve can also cause this issue, so clean it. Lastly, a weak spring valve can be the culprit, requiring you to replace the valve.
  • H
    Heidi MurrayAug 26, 2025
    How to fix contactor chatter in Market Forge Industries Boiler?
    • A
      aevansAug 26, 2025
      If the contactor chatters in your Market Forge Industries Boiler, first check that the supply voltage matches the coil contactors. If the contactor points are dirty or worn, clean or replace the contactor. A weak coil can also cause this, so replace it with the correct voltage coil.
  • T
    Tyler GreenAug 27, 2025
    What to do if water does not enter Market Forge Industries Boiler?
    • K
      kdavidsonAug 28, 2025
      If water isn't entering your Market Forge Industries Boiler, ensure the water main is turned on. Check the main fuse or circuit to make sure power is reaching the unit. If the probes are dirty, remove and clean them. If 120V is verified at the solenoid coil, but it fails to open, replace the solenoid.
  • M
    Michael Williams DVMAug 30, 2025
    Why does my Market Forge Industries Boiler shut down and fail to restart?
    • D
      David LaneAug 30, 2025
      If the Market Forge Industries Boiler builds up pressure, shuts down, and fails to come back on, the high limit switch might be set too low, or the operating pressure control switch set too high. Follow the instructions for readjusting, or replace if defective.
  • D
    Dr. Aaron Johnson IISep 1, 2025
    Why is the cold water condenser not working on my Market Forge Industries Boiler?
    • T
      tinacarpenterSep 1, 2025
      If the cold water condenser on your Market Forge Industries Boiler isn't functioning, ensure the main water line is turned on. If the thermostat is defective, replace it. Also, tighten the coil nut and check the solenoid coil for continuity; replace it if it's open.
  • S
    Shannon TranSep 2, 2025
    Why does the water level fluctuate in my Market Forge Industries Boiler?
    • L
      Lauren ShawSep 3, 2025
      If the water level in the gauge glass of your Market Forge Industries Boiler fluctuates up and down, the top shut off on the water gauge might be closed. Open it.
  • D
    Donna McneilSep 4, 2025
    Why does water enter Market Forge Industries Boiler so slowly?
    • M
      Miguel WolfeSep 5, 2025
      If water enters the Market Forge Industries boiler very slowly, the strainer screen in the solenoid valve might be dirty. Clean or replace the strainer screen.
  • K
    Kara StuartSep 7, 2025
    How to fix a leaking air vent on Market Forge Industries Boiler?
    • R
      Ronald SmithSep 7, 2025
      If the air vent on your Market Forge Industries Boiler is leaking, replace it.