10
8. Awning with lighting (two lamps per unit)
8.1 Overview
1 Lighting profile
2 Cap
3 Holder
4 Acrylic glass lighting tube colorless satin
finish
5 Fluorescent lamp
Osram FQ 39 W / 827
6 Mask
7 Starter casing
Electrical work: Electrical installations must be carried by a qualified electrician according to VDE 0100.
8.2 Lighting with dimmer
8.2.1
The cable for the lighting connection is
marked with this sticker.
The wiring diagram must definitely be observed, a
faulty connection can lead to the destruction of the
device!
Wire color Terminal
(1) gray Control voltage dimmer 10V (+)
(2) black Control voltage dimmer 10V (-)
(3) brown 230V~ voltage supply phase
(4) blue 230V~ voltage supply neutral
conductor
(5)
green/yellow
230V~ voltage supply protective
conductor
8.2.2
For the connection of the supply and control
cable, 5 approved screw terminals or non-screwed
terminals with a rated voltage of at least 230 V~
are required.
Attention Danger to Life: Electrical operation
without protective conductor connection is not
permitted! It is to be observed, that during operation
the protective conductor (5) green/yellow is neither
interrupted in/on the product nor by the mains cable.
All electrical connections and connection leads must
definitely be checked after being connected and
before the first trial operation!
8.2.3
Technical data of a lamp:
Power supply: 230 VAC
50 Hz (10/16A)
Max. wattage: 39W
Lamp: OSRAM FQ39W/827
System of protection: IP54
Supply cable cross-section: min. 1.0 mm²