20
CV Meaning Values Default
Note
50
PoM
Alternative Formats:
Bit 0 : Analog AC
Bit 1 : Analog DC
Bit 2 : fx (MM)
Bit 3 : mfx
0 / 1
0 / 2
0 / 4
0 / 8
15
Note:
DCC cannot deactivate itself.
66
PoM
Forward Trim 0 – 255 128
CV value divided by 128 gives the factor,
with which the speed level is multiplied in
forward running.
67
–
94
PoM
Speed Level Table 0 – 255
95
PoM
Reverse Trim 0 – 255 128
CV value divided by 128 gives the factor,
with which the speed level is multiplied in
reverse running.
112
PoM
113
PoM
114
PoM
Physical Output: Front Light(s) Mode
Physical Output: Front Light(s) Dimmer
Physical Output: Front Light(s) Period
0 – 15
0 – 255
0 – 255
1
255
20
See table page 16
115 –
123
PoM
Physical Output: Rear Light(s), Aux 1 to Aux 2
(each in the 3-way block)
See table page 16
137
PoM
Switching Range 0 – 128 128
128 = 50% Speed Level, 64 = 25% Speed
Level
257
PoM
262
PoM
267
PoM
Function Assignment: Funktion FL vorw.
Function Assignment: Funktion F1 vorw.
Function Assignment: Funktion F2 vorw.
0 – 63
0 – 63
0 – 63
1
4
8
See table page 16
357
PoM
362
PoM
367
PoM
Function Assignment: Funktion FL rev.
Function Assignment: Funktion F1 rev.
Function Assignment: Funktion F2 rev.
0 – 63
0 – 63
0 – 63
2
4
8
See table page 16