5
Problem: Erratic vertical movement
Cause: Another Laser Transmitter providing additional signal
Solution: Check for another Laser Transmitter on the job site
Cause: Radical Elevation changes
Solution: Slowdown in rough terrain
Cause: Laser beam reflection
Solution: Check for mirrored surfaces
Problem: Hydraulics do not respond when AUTOBLADE
button is pushed
Cause: JD Tractors Only
Solution: Tractor must be moving at least 1 MPH
If you are still experiencing problems with your system please call
us at (805) 583-0808 and we can assist you further.
Specifications
Input Power: 12 or 24 VDC Operation
Negative Ground
Nominal 10 amp minimum current
Note: If using 24VDC make sure to order correct Valves and Masts
Requirement: 10 amps Maximum
Output Hydraulic Drive: 5 amp Maximum per valve solenoid
2.5 amp maximum, if signal duration exceeds
two minutes
1 amp maximum output during short circuit
condition
Temperature Range: 20 to 50 Degrees C