Window Installation
StormPlust and Structural Installations
19970019
20120410
These instructions are applicable for the following StormPlus products:
Clad Casemaster
1
Wood Casemaster
1
Clad Ultimate Double Hung (CUDH)
2
Wood Ultimate Double Hung (WUDH)
2
Clad Direct Glaze Polygon/Round Top Wood Direct Glaze Polygon/Round Top
Clad Ultimate Double Hung Magnum Wood Ultimate Double Hung Magnum
1
Includes Awning, Operator, Picture 1, Stationary 3/4, Round Top Operator, and Round Top Stationary.
2
Includes Picture, Transom, Round Tops and Polygon
ABSTRACT
These instructions advise the window installer/carpenter/contractor on the recommended way to install Marvin
windows where structural installation is necessary, including those rated for use in Impact Zones 2 and 3. Exact
installation methods for Impact Zone 4 windows are NOT included. Instead, refer to the Notice of Acceptance (see
details inside).
In addition to steps for installing your window, included within are: Rough opening (RO) preparation for recessed
masonry applications; RO prep and sealing details for standard wood frame construction; detailed fastening
methods and more.
The procedures within these instructions are consistent with those used in testing to achieve the advertised DP
rating. Contact your local Marvin dealer if your construction scenario differs from those detailed within.
Regional standard practices, environmental conditions and codes may vary and supersede the
procedures contained within. The responsibility for compliance is yours: the installer, inspector, and
owner(s). See the Technical Installation Specifications inside for more details.
These instructions are applicable for the following Structural installations:
Clad Ultimate Double Hung Magnum Wood Ultimate Double Hung Magnum
NOTE: Certified IZ2 and IZ3 Casemaster, Ultimate Double Hung, and Direct Glaze Polygon/Round Top
units must be installed using jamb screws or structural brackets. Certified IZ3 Ultimate Double Hung
Magnum units must be installed using the jamb screw method only.
Question and Answer IconNeed help?

Do you have a question about the Marvin Window and is the answer not in the manual?

Marvin Window Specifications

General IconGeneral
BrandMarvin
ModelWindow
CategoryHousehold Appliance
LanguageEnglish

Summary

Abstract

Technical Installation Specifications

Before You Begin

Guidance for installers and builders before starting window installation.

Installer and Builder Information

Key responsibilities and information for installers and builders.

Aftermarket Products

Information regarding aftermarket products and their potential effects.

Hazard Notations

Explains safety notations and warnings used throughout the manual.

Rough Opening and Framing Requirements

Unit Preparation

Installing the Window

Fastening Methods and Jamb/Sill Screw Chart

Structural Brackets

Details on installing structural brackets for window fastening.

Jamb/Sill Screws

Information on using jamb and sill screws for fastening.

Special Fastening Systems

StormPlus Ultimate Double Hung IZ3 Storm Brackets

Instructions for installing IZ3 storm brackets on UDH units.

Final Installation Procedures

Continuous Air Barrier Systems – Preparing the Opening

Continuous Air Barrier Systems – Flashing the Installation

Removing Interior Stops, Liners, and Fillers

Removing Casemaster Stops and Covers

Procedures for removing stops and covers on Casemaster units.

Removing UDH Jamb Liners

Instructions for removing jamb liners from UDH units.

Removing Sash

Ultimate Double Hung Operator Sash

Steps for tilting and removing UDH operator sashes.

Casemaster Operator Sash

Procedures for removing Casemaster operator sashes.