5
ctric equipment and for use in residential, office
or light industrial environment but all electric
products imply a potential for electromagnetic
or other interference between the product and
other devices. If such interference is suspected
please disconnect the product from the mains
and consult a qualified technician, your supplier
or the manufacturer.
No special maintenance procedure is required
but if the product gets dusty or dirty it should be
wiped clean using a dry cloth while the product
is disconnected from the mains. No other main-
tenance should be necessary.
For products having a plastic casing, please
avoid any contact with lotions, oils, grease
and solvents as most types of plastic may be
degraded by such chemicals. Also make sure to
position, operate and store such products away
from UV-light and direct sunlight.
Position, operate and store this product only
under reasonable foreseeable environmental
conditions with respect to magnetic fields,
EM-fields, electrostatic discharges, pressure or
variations in pressure, acceleration etc.
If this product is used with or mounted in a
vehicle it may only be used when the vehicle is
not in use.
When in use, position this product so that the la-
bel can be read – within 40 cm of the operator.
This charger is a fast charger for NiCd/NiMH
batteries. The standard version utilizes a method
called -dV detection for charge termination when
the batteries are fully charged. This method is
based on the fact that the voltage drops over
the NiCd/NiMH cells when the batteries are fully
charged. This voltage drop is detected when the
voltage has dropped a certain percentage from
the highest value (typically 0.5%). lf this drop does
not occur, the charger has a safety timer which
will terminate charging after a given time period to
avoid overcharging the batteries. A few cells may
have a voltage drop in the first part of the charge
cycle. This is especially true for battery cells which
have been idle for a longer period of time. Because
of this, a start-timer is built into the charger which
prevents -dV detection the first minutes of the
charge cycle.
As the charger is programmable, it is possible that
the standard parameters, which this user manual
is based on, have been changed. See separate
user manual or contact supplier for additional
information.