5 SAFETY SWITCHES AND WARNING SIGNALS
The generators are equipped with a set of safety switches
which protect it against improper use and
problems which may jeopardise its integrity.
5.1 PROTECTION AGAINST SHORT-CIRCUITS AND OVERLOAD
The generator is protected against short-circuits and
electrical overload.
A magnetothermal switch (ref.1) cuts the power when
a short-circuit occurs or when the power delivered
exceeds the rated value.
Before restoring the contact, remove the cause
of the cutout.
5.2 PROTECTION AGAINST SHORT-CIRCUITS OF LOW-VOLTAGE
ELECTRICAL SYSTEM.
In the event of a short-circuit of the low-voltage electrical
system, two fuses 3A - 30A (ref.2) break the circuit
stopping the generator. In this case the warning lights
of the engine protection module will all be off and it will
not be possible to reattempt starting.
If one of the above safety switches trip, find and
eliminate the cause and then press the STOP button
to reset the control panel (otherwise the signal would
remain in memory inhibiting engine starting).