MS 8230B
DIGITAL MULTIMETER
01
INSTRUCTION MANUAL
Safety Information
To ensure s afe ope rat io n, an d in o rde r to e xpl oi t to th e full th e
func tiona lity of t he me te r, ple as e fol lo w the d irect ions in t his
sect ion car efu ll y.
Warning
This m ult imete r has b een des ign ed acco rdi ng to IEC -10 10
conc ern ing ele ctr onic me asu ring in str ument s wit h an over v olt age
cate gor y CAT II 10 00V, CAT III 6 00V and p oll ution 2 .
Foll ow al l safet y and o perat ing i nstru cti ons to en sur e that th e
mete r is us ed safe ly an d is kept i n goo d opera tin g condi tio n.
With p rop er use an d car e, the di git al mete r wil l give yo u yea rs of
sati sfa ctory s erv ice.
• Preli minary
- When u sin g the met er, th e user mu st ob serve a ll no rmal sa fet y
rule s con cerni ng:
Prot ect ion aga ins t the dan ger s of elec tri cal cur ren t.
Prot ect ion of th e met er agai nst m isuse .
- When t he me ter is de liv ered, c hec k that it h as no t been
dama ged i n trans it.
- When p oor c ondit ion u nder ha rsh p reser vat ion or sh ipp ing
cond iti ons cau sed , inspe ct an d confi rm th is mete r wit hout de lay.
- Test leads m ust b e in good c ond ition . Bef ore usi ng ve rif y th at
the in sul ation o n tes t leads i s not d amage d and /or the l ead s
wire i s not e xpose d.
- Full c omp lianc e wit h safet y sta ndard s can b e guara nte ed only
if use d wit h test le ads s uppli ed. I f neces sar y, th ey must b e
repl ace d with th e sam e model o r sam e elect ric r ating s.
• Durin g Use
- Befo re us ing, yo u mus t selec t the r ight in put j ack, fu nct ion and
rang e.
- Neve r exc eed the p rot ectio n lim it valu es in dicat ed in
spec ifi catio ns fo r each ra nge o f measu rem ent.
- When t he va lue sca le to b e measu red i s unkno wn be foreh and ,
set th e ran ge sele cto r at the hi ghe st posi tio n.
- Do not m eas ure vol tag e if the vo lta ge on the t erm inals e xce eds
1000 V abo ve eart h gro und.
- Alway s be ca reful w hen w orkin g wit h volta ges a bove 60 V DC or
30V AC rm s, ke ep fing ers b ehind t he pr obe bar rie rs whil e
meas uri ng.
- Befo re ro tatin g the t ransf orm s witch t o cha nge fun cti ons and
rang es, d iscon nec t test le ads f rom the c irc uit und er te st.
- Neve r per form re sis tance , tra nsist or an d diode m eas ureme nts
on liv e cir cuits .
- Neve r use t he mete r und er the co ndi tion of t he ex plosi ve ai r,
stea m or di rt.
- If any f aul ts o r abn orm aliti es ar e obser ved , the met er ca n not be
used a ny mo re and it h as to b e check ed ou t.
- Neve r use t he mete r unl ess the r ear c ase is in p lac e and fas ten ed
full y.
- Plea se do n ot stor e or us e meter i n are as expo sed t o direc t
sunl igh t, high t emp eratu re, h umidi ty or c onden sat ion.
• Symbo ls
Impo rta nt safe ty in forma tio n, refe r to th e opera tin g
manu al.
Doub le in sulat ion ( Prote cti on clas s II) .
Over vol tage (I nst allat ion ) categ ory I I, Poll uti on Degr ee 2
per IE C10 10-1 re fer s to the le vel o f Impul se Wi thsta nd
Volta ge pr otect ion p rovid ed.
Over vol tage (I nst allat ion ) categ ory I II, Pol lut ion Deg ree 2
per IE C10 10-1 re fer s to the le vel o f Impul se Wi thsta nd
Volta ge pr otect ion p rovid ed.
High v olt age war nin g symbo l
Conf orm s to euro pea n union d ire ctive
Eart h gro und
Fuse
Alte rna ting cu rre nt
CAT II
CAT III
-Ple ase d o not att emp t to adju st or r epair t he me ter by re mov ing
the re ar ca se whil e vol tage is b ein g appli ed. A tec hnici an wh o
full y und ersta nds d anger i nvo lved sh oul d only ca rry o ut such
acti ons .
- Befo re op ening t he ba ttery c ove r or case o f the m eter, al way s
disc onn ect tes t lea ds from a ll te sted ci rcu its.
- To avoid the w ron g readi ng ca usi ng e lec tri ci ty at tac k, w hen t he
mete r dis plays “ ” , you m us t cha nge t he b att ery.
- For co nti nue pro tec tion ag ain st fire , rep lace fu se on ly with t he
spec ifi ed volt age a nd curr ent r ating s: F 20 0mA/2 50V ( quick a cti ng).
- Do not u se ab rasiv es or s olven ts on t he mete r, use a d amp clo th
and mi ld de terge nt on ly.
- Alway s set t he powe r swi tch to th e OFF p ositi on wh en the me ter
is not i n use .
- If the m ete r is t o be st ore d fo r a lon g per iod of ti me, t he batt eri es
shou ld be r emove d to pr event d ama ge to the u nit .
• Maint enance
- This met er is a p ortab le pr ofess ion al meas uri ng in st rum ent w it h
hand som e LCD eas ily r eadin g.
- Sing le op erati on of a t ransf orm s witch m ake s measu rem ent
conv eni ent. Ov erl oad pro tec tion an d low b atter y ind icati on ar e
prov ide d, this m ete r is idea l for u se in the f iel ds, wor ksh op,
scho ol, h obby an d hom e appli cat ions.
- This met er is w ith the f unc tions o f dat a hold.
• Descr iption
02
Dire ct cu rrent
Diod e
This i ndi cates t hat t he disp lay d ata is be ing h eld.
The ba tte ry is not s uffic ient fo r pro per ope rat ion.
03
04
• Elect rical Spe cificat ions
Circ ums tance Tempe rat ure: 23 ± C, Rela tiv e Humid ity : < 75%
DC Voltag e
Rang e
200m V
2V
20V
200V
1000 V
Reso lut ion
0.1m V
0.00 1V
0.01 V
0.1V
1V
- Inpu t Imp edanc e: 1M Ω
- Over loa d Prote cti on: 200 mV ra nge: 25 0V DC o r AC rms,
2V- 1000V r ang es: 100 0V DC o r 750VAC r ms .
- Max. I npu t Voltag e: 10 00V DC
05
Accu rac y is spec ifi ed for a pe rio d of year a fte r calib rat ion and a t
18°C t o 2 C (64°F t o 8 F) w ith r ela tive hu mid ity to 75 %.
• Speci ficatio ns
- Max. Vo lta ge Betw een Termi nals And E art h Groun d: 10 00V D C
or 750 V AC
- Fuse P rot ectio n: F 20 0mA/2 50V ( quick a cti ng).
- Disp lay : 15mm LC D
- Max. S how Valu e: 1999 ( 3 1/2 )
- Pola rit y Indic ati on: '-' ind icate s neg ative p ola rity.
- Over ran ge Indi cat ion: Di spl ay '1'
- Samp lin g Time: ap pro x. 0.4 se con d
- Low Ba tte ry Indi cat ion: “ ”d isp layed
- Powe r Sup ply: 1. 5 3 AAA batte ry.
- Oper ati ng Temperat ure : 0°C to 40 °C (3 2°F to 10 4°F )
- Stor age Tempe ratur e: -1 0°C to 50 °C (1 0°F to 12 2°F )
- Dime nsi on & Weight : 158 ×74×3 2 mm, 2 50g (in clu din g ba tte ry)
• Gener al Specif ication s
Accu rac y
±(0. 5% of r dg + 2 digi ts)
±(0. 5% of r dg + 3 digi ts)
±(0. 8% of r dg + 3 digi ts)
±(0. 8% of r dg + 5 digi ts)
OFF
V
V
A
600V
CAT
III
1000V
CAT
II
MAX 10A
UNFUSED
FUSED
B ECE
FEh
NPN
1000
MAX 200mA
1000V
750V
Ω
10ADC
200
20
2
200m
2M
200k
20k
2k
200
10A
200m
20m
2m
200µ
200
750
VΩmA
PNP
COM
DIGITAL MULTIMETER
MS 8230B
OFF
V
V
A
600V
CAT
III
1000V
CAT
II
MAX 10A
UNFUSED
FUSED
B ECE
FEh
NPN
1000
MAX 200mA
1000V
750V
Ω
10ADC
200
20
2
200m
2M
200k
20k
2k
200
10A
200m
20m
2m
200µ
200
750
VΩmA
PNP
COM
DIGITAL MULTIMETER
MS 8230B
1
2
3
4
5
6
7
8
• Names o f
Compo nen ts
LCD Di spl ay
Pane l
H Butt on:
This B utt on is
used t o the s witch
of dat a hol d.
Tra nsf or m Swi tch :
This s wit ch is use d
to sel ect f uncti ons
and de sir ed rang es.
1
2
3
4
10A Jac k:
Inpu t ter minal
for cu rre nt 0 ~ 10A.
COM Ja ck:
Comm on te rmina l
for me asu remen t.
hFE Ja ck:
This J ack i s used to
tran sis tor tes t.
V/Ω/ mA Jac k:
Inpu t Jac k
5
7
6
8
FR O N T PA N E L

Other manuals for Mastech MS8230B

Question and Answer IconNeed help?

Do you have a question about the Mastech MS8230B and is the answer not in the manual?

Mastech MS8230B Specifications

General IconGeneral
BrandMastech
ModelMS8230B
CategoryMultimeter
LanguageEnglish

Summary

Safety Information

Preliminary Safety Checks

User must observe all normal safety rules before using the meter.

Safe Operation During Use

Precautions and guidelines for safe operation while using the multimeter.

Understanding Symbols

Explanation of safety and operational symbols used in the manual.

Meter Maintenance Guidelines

Procedures for upkeep, care, and ensuring the meter's longevity.

Product Description

Overview of the multimeter's features, design, and intended applications.

Front Panel Overview

Component Identification

Identifies and describes the various parts and controls on the multimeter's front panel.

Technical Specifications

General Specifications

Lists overall technical parameters and characteristics of the multimeter.

Electrical Specifications

Details performance data for DC Voltage, AC Voltage, Current, Resistance, Diode, and Transistor tests.

Operating Instructions

Data Hold Function

How to use the data hold feature to freeze readings on the LCD display.

Measurement Preparation

Steps to prepare the meter for measurement, including battery check and range selection.

Measuring DC Voltage

Procedure for safely and accurately measuring DC voltage.

Measuring AC Voltage

Procedure for safely and accurately measuring AC voltage.

Measuring DC Current

Procedure for safely and accurately measuring DC current, including jack usage.

Measuring Resistance

Procedure for safely and accurately measuring resistance, with power off precautions.

Testing Diodes

How to test diodes using the multimeter, including forward voltage drop readings.

Testing Transistors

Procedure for testing transistor hFE values using the dedicated socket.

Maintenance and Replacement

Battery Replacement

Instructions for replacing the meter's battery safely.

Fuse Replacement

Guidance on replacing fuses with correct ratings to prevent fire hazards.

Test Leads Replacement

Information on replacing test leads to maintain safety and compliance.

Included Accessories

Accessory List

Lists the items included with the multimeter, such as test leads and manual.