EasyManua.ls Logo

Master Bilt CCR-49DF User Manual

Master Bilt CCR-49DF
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
VISION CREATIVE, INC.
중구 남대문로 5 526
대우재단빌딩 16
김세호님 TEL
MODEL
CCR-23SR,49DR,72TR/WCC-23SR/WCR-23SR/CCR-23SF,49DF,72TF/WCR-23SF
BUYER
1 03.2.7 6
2 03.2.13 7
일정 3 03.7.22 8차
4차 03.7.25 9차
5차 03.7.28 10
제판 03.7.28(Han)출력
규격
MEMO
03.12.15-3page-수정 (6)추가
VVIISSIIOONN
박선민
TEL: 757-9340 FAX: 774-
1039
Question and Answer IconNeed help?

Do you have a question about the Master Bilt CCR-49DF and is the answer not in the manual?

Master Bilt CCR-49DF Specifications

General IconGeneral
CategoryRefrigerator
ModelCCR-49DF
TypeCommercial Refrigerator
Capacity49 cu. ft.
Number of Doors2
Defrost TypeAutomatic
Shelves6
Exterior MaterialStainless Steel
Interior MaterialAluminum
Power Supply115V/60Hz
Door TypeSolid
CertificationsNSF

Summary

Installation Guidelines

Good Air Circulation

Avoid partitions/objects restricting airflow and ensure sufficient air space at the rear.

Placement and Environment

Do not place near heat sources; ensure indoor usage only.

Stabilizing and Leveling

Lock front wheels for stability and ensure the unit is level.

Electrical Connection

Unit must be connected to a dedicated outlet.

Cleaning and Safety

Cleaning Procedures

Clean interior/exterior with soap/water, condenser fins periodically, and door gaskets.

Safety Precautions

Ensure proper power cord connection and wait 5 minutes before re-starting.

Basic Operation - Refrigerators

Temperature Control

Adjust the thermostat (Cool/Cold) for desired temperature; factory setting is 'Normal'.

Light and Fan Operation

Interior light activates with door opening; fans activate when door is fully closed.

Basic Operation - Refrigerators (Electronic Control)

Power On and Temperature Setting

Plug in, turn on power; default setting is '5', adjustable from 1-9.

Automatic Cycles and Indicators

Details compressor cycling, defrost control, interior light, and fan operation.

Refrigerator Display Panel

Temperature Settings and Controls

Covers temperature setting, control buttons, and the inner temperature display.

Operational Indicators

Explains indicators for Quick Cooling, Fan Running, and Door Opening.

Quick Cooling Function

Details the Quick Cooling button and its indicator.

Refrigerator Advanced Operations

Quick Cooling Function

Initiate rapid cooling; compressor runs until -10°C or 120 min max; temp buttons inactive.

Temperature Adjustment

Use Up/Down buttons to set temperature from 1 (higher) to 9 (lower); auto-locks after 5 seconds.

Refrigerator Indicator Descriptions

Inner Temperature Display

Displays temperature 14°F-69°F; shows 'LO' below 14°F and 'HI' above 69°F.

Fan and Door Indicators

Fan indicator for running; door indicator for opening with warning beeps.

Basic Operation - Freezers

Power, Temperature, and Defrost

Covers powering on, default setting '5', electronic control, and defrost cycle.

Light, Fan, and Airflow

Details interior light, fan operation, and critical airflow requirements for freezers.

Freezer Display Panel

Temperature Settings and Controls

Covers temperature setting, control buttons, and the inner temperature display.

Operational Indicators

Explains indicators for D.F., Fan, Door, Manual Defrost, and Door Opening.

Manual Defrost Function

Details the manual defrost button and its indicator.

Freezer Operations (CCR Models)

Manual Defrost Operation

Start defrost by holding the button for 5 seconds; temp controls inactive during manual defrost.

Temperature Control

Use Up/Down buttons to set temperature from 1 to 9.

Automatic Defrost Cycle

Factory set every 6 hours; coil heats until 60°F; panel displays 'd F' during cycle.

Freezer Operations (WCR Model)

Manual Defrost Operation

Start defrost by holding the button for 5 seconds; temp controls inactive during manual defrost.

Temperature Control and Locking

Set temperature 1-9; lock function prevents unauthorized changes; auto-locks after 5 seconds.

Automatic Defrost Cycle

Factory set every 6 hours; coil heats until 60°F; panel displays 'd F' during cycle.

Freezer Indicator Descriptions

Inner Temperature Display

Displays temperature -50°F to +50°F; shows 'LO' below -50°F and 'HI' above +50°F.

Fan and Door Indicators

Fan indicator for running; door indicator for opening with warning beeps.

Reverse Door Installation Method

Grill and Wire Disconnection

Remove bottom/top grills, caps; disconnect heater wire from main harness.

Hinge Bolt Removal

Unscrew bolts at top hinge (3 points) and bottom hinge (3 points).

Door Assembly Removal

Remove the door assembly; caution regarding heater wire damage.

Fixture Substitution and Re-assembly

Swap fixtures, fix hinges, setup door, pull wire, connect wire, assemble caps/grills.

Troubleshooting and Non-Malfunctions

Addressing Unit Issues

Covers melting food, no/poor refrigeration, loud noise, dew drops, and door closing problems.

Identifying Normal Sounds

Clarifies that refrigerant flow and defrost sounds are not malfunctions.

Warranty Information

Limited One Year Warranty

Covers defects in material/workmanship for one year, including labor for authorized service.

Extended Compressor Warranty

Provides an additional four years of warranty specifically for compressor replacement against defects.

Terms of Sale

Pricing, Delivery, and Shipment

Details pricing policies, approximate delivery, carrier selection, and F.O.B. factory.

Damage Claims and Taxes

Procedure for transit damage claims and note that taxes are not included in prices.

Cancellations and Returns

Compensation for cancellations and policy for authorized product returns with handling charges.

Warranty Summary in Terms

Summarizes included one year parts/labor and four year compressor warranty for US/Canada sales.