Troubleshooting
Problem: Water conditioner fails to regenerate.
Power supply to MP-MCA control
has been interrupted.
Determine reason for power
interruption and correct. Reset time of
day.
Corrupted programming of MP-
MCA timer.
Reprogram timer assembly.
Manual bypass valve is open.
Close manual bypass valve.
Insure that riser pipe is properly
sealed at o’ring seal. Inspect pipe for
cracks.
Check brine float height and clean
assembly if necessary. Check flow
rate capabilities of safety float and air
check assembly.
Plugged injector or injector screen.
Inspect and clean injector and/or
injector screen.
Plugged injector or injector screen.
Inspect and clean injector and/or
injector screen.
Insufficient water pressure.
Increase water pressure above 25
psig (172kPa) minimum.
Corrupted programming of MP-
MCA timer.
Reprogram timer assembly.