REGULATION
Depending on the type of generator, the
appliance heat capacity can be regulated.
The heat capacity can be regulated by
acting on the knob positioned on the
base of the generator (Fig. 22) or on
the pressure regulator installed on the
gas cylinder (Fig. 23), depending on the
model.
9. SWITCH-OFF FOR MANUAL
MODELS (... / ...M / ...DV)
9.1.Close the gas cylinder (Fig. 24).
9.2.Leave the fan to cool for about 60
s, in order to prevent internal damage
due to overheating (generator internal
cooling).
9.3.Take the “O/I” switch to position “O”
(Fig. 25).
9.4.Disconnect the generator from the
mains electricity (Fig. 26).
9.5.Disconnect the generator from the
gas supply pipe (Fig. 27-28-29).
10. SWITCH-OFF FOR
ELECTRONIC MODELS (...E)
10.1.Take the “O/I” switch to position
“O” (Fig. 25). The ame goes out and the
generator performs the post-ventilation
phase. Wait for the cycle to be completed
in order to prevent internal damage due
to overheating (the phase is automatic
and can last 50 s÷5 min depending on
the internal/external temperature at the
generator).
►10.2.Close the gas cylinder (Fig. 24).
►10.3.Disconnect the generator from
the mains electricity (Fig. 26).
►10.4.Disconnect the generator from
the gas supply pipe (Fig. 27-28-29).
N.B.: Do not disconnect the generator
from the mains electricity, before the
end of the post-ventilation phase, in
order to prevent internal damage due
to over-heating.

MAINTENANCE
Have the after-sales assistance check
correct functioning of the generator at
least once a year and/or as required. The
appliance must be cleaned before it is
put away after use.
►11.1.Before starting any type of
maintenance, care and repairs of the
appliance, carry out the switch-off
sequence [Par. 9. “SWITCH-OFF FOR
MANUAL MODELS (... / ...M / ...DV)or
10. SWITCH-OFF FOR ELECTRONIC
MODELS (...E)”].
►11.2.Cleaning only concerns the air
vent (rear side) of the generator.
►11.3.When the appliance is used
again, check the state of integrity of the
gas hose and power supply cable. If in
doubt regarding their integrity, request
the assistance of the technical after-sales
service.
►11.4.Do not carry out unauthorised
interventions.

CONNECTION (...E) (optional)
Remove the plug connected to the
appliance and connect the room
thermostat (optional) (Fig. 30).
See wiring diagram (...E).
en
it
de
es
fr
nl
pt
da
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Master 17 and is the answer not in the manual?

Master 17 Specifications

General IconGeneral
BrandMaster
Model17
CategoryPower Tool
LanguageEnglish

Related product manuals