FUNCTIONING
ANOMALIES
...
...M
...DV
...E CAUSES SOLUTIONS
The motor does
not start
X X No voltage 1°Check the mains
system
2°After-sales
assistance
X X Power supply cable
faulty/damaged
After-sales assistance
X X Faulty motor After-sales assistance
X Incorrect connection
of the room
thermostat
Connect the room
thermostat correctly
The ame does
not ignite
X X Gas cylinder empty Replace the gas
cylinder (Par. 4)
X X Regulator safety
valve blocked
1°Press the regulator
gas release button
(Fig. 13)
2°After-sales
assistance
X X Gas cylinder cock
closed
Open the gas cylinder
cock (Fig. 12)
X X Faulty ignition circuit After-sales assistance
X Inefcient earthing Check your system is
earthed correctly
The ame does
not stay on
X Gas button not
pressed for long
enough
Press the gas button
for longer (Par. 6.1.4.)
X X Faulty generator After-sales assistance
Flame goes out
during functioning
X X Insufcient gas
supply
1°Replace the gas
cylinder (Par. 4)
2°After-sales
assistance
X X No gasication of the
fuel
Use gas cylinders with
suitable capacity (Par.
4)
X X Appliance
overheating
1°Clean the air vent
(rear side)
2°After-sales
assistance
X X Faulty generator After-sales assistance
en
it
de
es
fr
nl
pt
da
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Master 17 and is the answer not in the manual?

Master 17 Specifications

General IconGeneral
BrandMaster
Model17
CategoryPower Tool
LanguageEnglish

Related product manuals