EasyManua.ls Logo

Master BLP 15 kW M - User Manual

Master BLP 15 kW M
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
4162.739
Ediction 09
Rev. 10
0085
Operation and maintenance manual - Příručka pro provoz a údržbu
- Üzemeltetési és karbantartási kézikönyv - Manual de utilizare
si intretinere - Упътване за експлоатация - Książĸa instrukcji
eksploatacji oraz naprawy - Руководстьо по эксплуатации
- Naudojimosi instrukcija - Lietošanas un apkopes instrukcija -
Kasutus-ja hooldusjuhend - Priročnik - Uputa o pogonu i održavanju
GB - “LPG” Hot air generator
CZ - Horkovzdušné vytápěcí zařízení
HU - Légfütö berendezés
RO - Generator de aer cald pe gaz ”LPG”
BG - Преносим калорифер
PL - Urządzenie ogrzewcze powietrza
RU - Нагревательный прибор
LT - ”LPG” Dujinis oro šildytuvas
LV - ”LPG” Gāzes sildītājs
EE - ”LPG” Kuumaõhoupuhur
SK -
Teplovzdušné vykurovacie zariadenie
SI - Priprava za vpihavanje toploga zraka
HR - Uređaj za upuh toploga zraka
BLP 10 kW M
BLP 14 kW M
BLP 15 kW M
BLP 25 kW M
BLP 30 kW M
BLP 53 kW M
BLP 73 kW M
BLP 25 kW M DV
BLP 30 kW M DV
BLP 53 kW M DV
BLP 73 kW M DV

Questions and Answers

  • T
    Theresa CooperAug 11, 2025
    What to do if the flame goes out during operation of my Master Portable Generator?
    • M
      Michael JeffersonAug 11, 2025
      If the flame goes out during operation, it could be due to insufficient gas supply. In this case, replace the cylinder. Alternatively, the appliance might be overheating excessively because of insufficient air supply.
  • M
    maria81Aug 16, 2025
    Why the flame does not ignite in my Master Portable Generator?
    • L
      latoyachoiAug 16, 2025
      The flame might fail to ignite in your Master Portable Generator due to several reasons: there could be excessive distance between the electrode and burner, in which case you should adjust the distance. Another reason may be lack of gas - replace the cylinder. It could also be due to a faulty gas valve, which requires specialized work. Finally, check if the safety valves have tripped and, if so, press the push-button to reset the safety valve.
  • A
    adam49Aug 23, 2025
    What to do if the motor does not turn on in my Master Portable Generator?
    • H
      hardylindaAug 23, 2025
      If the motor on your Master Portable Generator doesn't turn on, the possible causes are: a faulty mains cable, a faulty fan, or a faulty switch. In each of these cases, you should replace or repair the faulty component.
  • D
    Duane CunninghamAug 29, 2025
    Why does the flame go out after a few seconds of ignition in my Master Portable Generator?
    • J
      John VangAug 29, 2025
      The flame might be going out after a few seconds due to several reasons. Check the distance between the temperature sensor and the burner; if it's excessive, adjust it. Also, ensure you're holding the gas button pressed long enough, up to 20 seconds maximum. Other potential causes include a faulty safety chain (specialized work needed) or the appliance overheating, in which case you should wait 5 minutes for the safety thermostat to cool down before restarting.
  • M
    mariah88Sep 3, 2025
    How to fix a yellow luminous outline flame in my Master Portable Generator?
    • T
      Todd Wallace DDSSep 3, 2025
      A yellow luminous outline on the flame of your Master Portable Generator indicates an air fault in the burner, so you should clean the air inlet. It may also indicate an excess of gas in the burner; in this case, adjust the pressure and/or replace the nozzle.