Troubleshooting
Problem: Water conditioner fails to regenerate. No soft water.
Power supply to MCA control has
been interrupted.
Determine reason for power
interruption and correct. Reset time of
day.
Corrupted programming of MCA
timer.
Reprogram timer assembly.
Manual bypass valve is open.
Close manual bypass valve.
Insure that riser pipe is properly
sealed at o’ring seal. Inspect pipe for
cracks.
Check brine float height and clean
assembly if necessary. Check flow
rate capabilities of safety float and air
check assembly.
Plugged injector or injector screen.
Inspect and clean injector and/or
injector screen.
Plugged injector or injector screen.
Inspect and clean injector and/or
injector screen.
Insufficient water pressure.
Increase water pressure above 25
psig (172kPa) minimum.
Corrupted programming of MCA
timer.
Reprogram timer assembly.