No flow control installed in drain
line.
Install drain line flow control.
Insufficient water pressure.
Increase water pressure above 25
psig (172kPa) minimum.
Damaged valve disk or obstruction
in valve disk.
Inspect and if damaged, replace all
valve disks or remove obstruction.
Problem: Loss of Water Pressure
Fouled resin bed due to iron
accumulation.
Clean control valve and mineral bed
with cleaner.
Slots in riser pipe or laterals are
filled with resin fines.
Inspect and clean distributor pipe slots
as needed.
Problem: Salt in Water to Service after Regeneration
Injector is too small for system size.
Brine draw time excessively long
due to low water pressure.
Increase water pressure above 25
psig (172 kPa) minimum.
Remove drain line restriction.
Insufficient rinse volume.
Increase slow rinse time, fast rinse
time, or both.
Plugged injector and/or injector
screen.
Inspect and clean injector and/or
injector screen.