headline bars
55
headline bars
Engine is running
but no AC output.
Poor cord connection Check all connections.
Circuit breaker is open. Reset circuit breaker.
Faulty brush assembly Replace brush assembly (Service
Centre).
Faulty AVR (auto voltage
regulator)
Replace AVR (Service Centre).
Loose wiring Inspect and tighten wiring connections.
Other Contact the help line.
Engine hunts or
falters.
Engine governor defective Contact the help line.
Dirty fuel valve Clean the fuel valve.
Carburetor is dirty and running
lean.
Contact the help line.
Choke in wrong position Move choke until it stops under RUN
position or push in completely.
Repeated circuit
breaker tripping.
Overload Review load and adjust. See “Do not
Overload Generator” (page 29).
Faulty power cords or device Check for damaged, bare or frayed
wires. Replace defective device.
Circuit breaker still too hot Let unit sit for 5 mins.
TROUBLESHOOTING