16
03
AC input voltage range
Appliances (default)
If selected, acceptable AC
input voltage range will be
within 90-280VAC.
UPS
If selected, acceptable AC
input voltage range will be
within 170-280VAC.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected,
battery charge voltage and
low DC cut-off voltage can be
set up in program 26, 27 and
29.
Pylontech battery
If selected, programs of 02,
26, 27 and 29 will be
automatically set up. No need
for further setting.
WECO battery (only for 48V
model)
If selected, programs of 02,
12, 26, 27 and 29 will be
auto-configured per battery
supplier recommended. No
need for further adjustment.