45
All of Inverters:
When “ALL” is selected, parallel or 3-phase
system will continue working according to
rule of “solar firstsetting only when all of
inverters are connected to PV modules.
For example, two units are connected in
parallel and set “SOLin output source
priority. When selecting “ALL” in program
30, it’s necessary to have all inverters
connected to PV modules and PV input is
normal to allow the system to provide
power to loads from solar and battery
power. Otherwise, the system will provide
power to loads from utility.
Fault code display:
Fault Code
Fault Event
Icon on
60
Power feedback protection
71
Firmware version inconsistent
72
Current sharing fault
80
CAN fault
81
Host loss
82
Synchronization loss
83
Battery voltage detected different
84
AC input voltage and frequency detected different
85
AC output current unbalance
86
AC output mode setting is different