EasyManuals Logo

Matrix MCS 46-45 User Manual

Matrix MCS 46-45
Go to English
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
42
Problem Possible cause Remedy
The engine cuts out. Incorrect carburettor setting The carburetor can be adjusted
by a professional.
or
please contact service center.
The engine starts but
delivers very little power.
Incorrect choke lever setting
Air lter dirty
Incorrect carburettor setting
Set it to
Remove the air lter, clean it with
soap suds, dry it and then t it
again.
Have the carburettor adjusted by
a specialist.
The engine does not start or
starts but then cuts out again.
Incorrect starting procedure
Incorrect carburettor setting
Sooted spark plug
Follow the instructions in “Start
when the engine is cold”
Have the carburettor adjusted by
a specialist.
Clean the spark plug, correct the
electrode gap or replace the
spark plug.
The engine runs unevenly. Incorrect electrode gap on the
spark plug
Burned spark plug
Clean the spark plug, correct the
electrode gap (ideally 0.25”/0.63
mm) or replace the spark plug.
Excessive smoke development. Incorrect carburettor setting
Incorrect fuel mixture
Have the carburettor adjusted by
a specialist.
Empty the tank, and rell it with
the correct mixture: 2-stroke,
ratio 40:1
Residual risks
Even when properly used in the tool is always
some residual risk that can not be excluded. From
the nature and design of the tool, the following
potential hazards can be derived :
- Contact with the unprotected chain ( cuts);
- Reaching into the running saw chain (cut injury);
- Unexpected , sudden movement of the guide
rail ( cuts);
- Ejection of parts of the chain;
- Ejection of parts of the material to be cut;
- Impairment of hearing , if there is no prescribed
hearing protection is worn;
- Inhalation of of material to be cut;
- Risk of kickback;
- This device produces an electromagnetic eld
during operation ! This eld can interfere with
active or passive medical implants under certain
circumstances!
To reduce the risk of serious or fatal injury , we
recommend persons with medical implants their
physician and the manufacturer of the medical
implant consulted before the instrument is used !

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Matrix MCS 46-45 and is the answer not in the manual?

Matrix MCS 46-45 Specifications

General IconGeneral
BrandMatrix
ModelMCS 46-45
CategoryChainsaw
LanguageEnglish