Smokehouse MAUTING Junior
Date:
1.7.2006
Worked out:
Fila Petr
Checked by:
Bielak Antonin Ing.
Approved by:
Bielak Antonin Ing.
Version No: 3 Page:
19 of 22
Instruction manual
Malfunction
Malfunction cause Troubleshooting
Humidity does
not increase
Water input is closed
Open the water ball valve
Clean water filter, check water distribution
Solenoid valve does not
work correctly
Exchange coil or the whole valve
Clogged nozzle Clean nozzle
Chamber
overheating
Control light on switchboard
box is on, control unit
display shows in low light
intensity and fan stops
Push alight control button (fan will start,
temperature in chamber will decrease under
set value, display will light up, fan will stop)
Switch on and off the main power switch
Temperature sensor in
chamber is damaged
Exchange temperature sensor in chamber
Control unit is damaged Contact manufacturer
Temperature is
5°C above set
value
Contacts of electromagnetic
switch are clotted
Exchange electromagnetic switch
Main fan does
not work
Control light on switchboard
box is off, control unit
display lights and fan stops
Failure unblocking:
Switch off the main power switch, remove
cover of switchboard box and push button
„START“ on circuit breaker F5
Press lighted control button (the circulatory
fan starts running, chamber temperature
decreases under set limit, display of
regulator lights up, circulatory fan stops)
Electric motor or input cable
are damaged
Check input cable to electric motor and
motor
GUARANTEE AND AFTER GUARANTEE SERVICE PROVIDE THE
MANUFACTURER OR AN AUTHORIZED COMPANY