Smokehouse MAUTING Junior
Date:
1.7.2006
Worked out:
Fila Petr
Checked by:
Bielak Antonin Ing.
Approved by:
Bielak Antonin Ing.
Version No: 3 Page:
18 of 22
Instruction manual
10. MALFUNCTIONS AND THEIR REPAIRS
Please, see the description of the most probable failure causes of the chamber. It is supposed
well-trained operator and well-done program in the control unit.
Malfunction
Malfunction cause Troubleshooting
Temperature in
chamber does not
increase
Control unit fault,
temperature sensor fault
Check control unit and parts of switchboard
Heating element damage,
disconnected input
Repair or exchange input cables, exchange
heating elements
No smoke in
chamber
There are no wooden chips
in drawer
Fill in wooden chips
Heating element does not
work
Check heating element and parts of
switchboard
Low density of
smoke
Dirty bottom of the wooden
chip drawer
Clean smoke generator
Use recommended wooden chips
Display shows
running program
and equipment does not
work
Circuit breaker is off or fuse
is burned
Check circuit breaker FO, put it on,
exchange fuse P01
After switch on
the main power
switch is not
possible to start control
unit by button „ON
Circuit breaker is off
Check and put on circuit breakers F9 and
F9.1
Control unit is
damaged or shows
error messages
Incorrect handling
See error messages in the booklet
Instructions for Programming, contact
manufacturer
Control unit shows error
messages due to sensor
damages
See error messages in the booklet
Instructions for Programming, according to
kind of flaw, repair or exchange cable or
sensor