Instrucon Manual
POWER ON/OFF
Press buon once to power on
Press & hold the buon 3 seconds to turn off the thermometer.
C/F (CALIBRATION)
Press for Fahrenheit or Cengrade for temperature reading.
Press & hold buon for 5 sec for Re-Calibraon)
MAX/MIN -CLEAR
Press once to Maximum temperature recorded;
press again to show Minimum temperature recorded.
Press and hold to erase the current Maximum
or Minimum temperature recorded
RESET
Press the buon to reset the thermometer to factory default
HOLD / BACKLIGHT
Press once to hold temperature recorded,
press again to un-hold
Every press of this buon turns on the backlight for 5 seconds
1. To insert the baeries
Use a coin to open the baery door at the back of unit by turning it from LOCK to UNLOCK.
Insert Two CR2032 Lithium baeries with + sign up. Fasten the baery door securely but do not over-turn.
(The water resistance features requires maintaining the rubber gasket evenly within the groove.)
2. Temperature Scale
To select temperature reading in Fahrenheit or Cengrade by pressing buon.
3. Geng Started
Press buon once to turn on the thermometer.
Press buon once to show Maximum temperature recorded with showing “MAX” icon.
Press again to show Minimum temperature recorded with showing “MIN” icon.
Press and hold buon again to erase the current Maximum or Minimum temperature
recorded. The LCD will show “---“ to indicate the temperature record is erased.
Press buon once lock the current temperature displayed on thermometer.
The LCD will show “HOLD” icon. Press again to release the locked temperature reading,
the “HOLD” icon will be off and back to current temperature display.
Backlight will be turned on for beer viewing.
5. Baery Status
When the voltage on baery is low, Low Baery Indicator will be shown on LCD.
Please replace with new baeries.
6. Manual / Auto Power O
- Press and hold buon for 3 seconds to turn off the thermometer for power saving
- Press buon again to turn on the thermometer
- The thermometer will automacally power off if no buons are pressed for ten minutes.
SP ECIFIC AT I O NS:
Operang Range : -4°F to 572°F / -20°C to +300°C
Display Range : -4°F to 572°F / -20°C to +300°C
Power : 2 x CR2032
CA R E OF YOUR PR ODUCT
Don't touch the probe p with bare fingers aer use to avoid burning fingers.
Although this thermometer is waterproof do not wash in dishwasher.
Don't put the thermometer probe inside the oven or microwave oven and always keep at least 6
away from any heat source.
The thermometer probe is made of food-grade stainless steel and is designed for instant
measurement only.
Don't measure temperatures above 300°C /572°F. Never burn probe directly over fire. Doing so ,
the thermometer screen will show “ H I ” and connuously using at this temperature will cause
permanent probe damage,
Use damp cloth or sponge to clean the probe and dry thoroughly aer cooking,
Don't subject the thermometer to extreme temperatures, humidity or severe shock.
Don't clean the case with any corrosive materials such as perfume, alcohol or cleaning agent or abrasives.
Keep the baeries, stainless steel probe away from children.
C/F
C/F
C/F
C/F
US DA SA F E FOOD T E MPERATUR ES*
C/F
C/F
(Calibration) (Clear)
RESET
LIGHT / HOLD
DISPLAY
BATTERY DOOR
FOLDABLE PROBE
POWER
MAX/MIN
Maverick Rain Drop Waterproof Digital Thermometer
Model no. PT-55
Congratulaons on the purchase of your new Waterproof thermometer tested to IP67.
Your thermometer is able to be immersed in up to 3  of water for up to 30 minutes.
4. RE-C A L IBRATION of Thermometer
- Make ice bath with 3 parts ice and 1 part cold water.
- Insert the probe p into center of ice bath.
- Press and hold buon for 5 seconds unl the unit show “CAL”
- The thermometer will start calibraon range from -3C /+26.6F to +2C /+35.6F to an accurate 0C /+32F
Note: Water boils at 208 F/97.8 C at 2000  above sea level
Question and Answer IconNeed help?

Do you have a question about the Maverick PT-55 and is the answer not in the manual?

Maverick PT-55 Specifications

General IconGeneral
BrandMaverick
ModelPT-55
CategoryThermometer
LanguageEnglish

Summary

Thermometer Operation Guide

Power On/Off

Turns the thermometer on by pressing the button once, and off by holding the button for 3 seconds.

Temperature Scale Selection

Selects between Fahrenheit or Centigrade for temperature readings by pressing the C/F button.

Max/Min Temperature Display and Clear

Shows recorded max/min temperatures and erases them by pressing the MAX/MIN button.

Reset to Factory Defaults

Resets the thermometer to its original factory settings by pressing the RESET button.

Hold Temperature and Backlight

Locks the current temperature reading and activates the backlight for 5 seconds.

Using the Thermometer

Battery Installation

Instructions for opening the battery door, inserting two CR2032 batteries, and securing the door.

Getting Started and Basic Functions

Covers powering on, viewing max/min temps, holding readings, and backlight activation.

Re-Calibration Procedure

Details on performing a re-calibration using an ice bath for accuracy.

Battery Status Indicator

Explains the low battery indicator and the need for battery replacement.

Power Management (Manual/Auto)

Describes manual power off and automatic power off after 10 minutes of inactivity.

Specifications and Care

Product Specifications

Lists operating and display ranges, and power requirements for the thermometer.

Product Care and Safety

Guidelines on handling, cleaning, avoiding heat sources, and safety precautions.

Disposal and Warranty Information

Disposal of Old Product

Instructions for environmentally responsible disposal of old electrical products.

Disposal of Batteries

Guidance on the proper disposal of flat batteries and accumulators.

Limited Warranty Terms

Details the 90-day limited warranty, service instructions, and conditions.