20
MAX Arm/Ultra Arm V1b.3
5
wire arm(s) to dsp board
115VAC
3A max
WARNING: For continued p
r
against fire, replace only
same type and rating
AVERTISSEMENT: pour ne pas compr
o
protection contre les risques d’incendie,
u
fusible de mêmes type et caractéristiques n
o
SAFETYCENTEREXIT
J3
J2
J4 J5
EXIT
PWR
MOTOR 2MOTOR 1
SOLAR MODE
CLOSING GATE SPEED
UL
ENTRA
P
MAGLOC
DELAY
GND
GND
GND
TAMPER IN
TAMPER NO
GATE DISABLE
KEYPAD/CARD
GND
GND
MAX OPEN
FIRE DEPT
RADIO GND
RADIO SIGNAL
STRIKE
CLOSE
COM
COM
STOP
OPEN
24VDC OUTPUT
12VDC OUTPUT
GND
GND
GND
LOOP
LOOP PWR
LOOP
CENTER
SAFETY
OFF
SINGLE DUAL
ON
ANTI
-
TAILGATE
PUSH
OPEN
PULL
OPEN
GATE
OFF
MIN
MIN
MAX
MAX
ON
OFF 2.5
1.5 sec
FAULTS
OPERATOR
EXIT LOOP
4
ground control box
Operator MUST be Properly GROUNDED
IMPORTANT: Operator MUST be grounded in lightning
prone areas or warranty will be VOIDED!
NOTE: Consult city codes for AC line wiring.
Beware of existing underground services.
Proper grounding of this control box is a requirement for
LIGHTNING PROTECTION in lightning prone areas. To be
effective, ground connections should be made with a minimum
12 AWG, 600 volt insulated wire to a ground point within 10 feet
of the control box. The ground point must be at an electrical
panel, a metallic cold water pipe that runs in the earth, or a
grounding rod.
Chassis
Ground
Grounding Rod
M
OTOR 2
ERD
MOTOR
OVER
LOAD
MIN MAX
OFF
O
L
P
EED
MOTOR 2
LIMITS
MAG
LOCK
UL
ENTRAP
L
OSE
CLOSE
TIMER
MAGLOCK
DELAY
JOG
GATE OPEN
GND
OPEN ONLY NC
OPEN ONLY 10K
PHOTO CLS NC
OPEN / CLS NC
GND
12VDC OUT
GND
GND
GND
JOG CLOSE
JOG OPEN
TAMPER IN
TAMPER NO
GATE DISABLE
CLOSE
COM
COM
STOP
CLS ONLY 10K
OPEN / CLS 10K
12VDC OUT
NO
COM
NC
COM
GATE CLOSED
LIMIT 1
GND
LIMIT 2
MOTOR 1
LIMITS
MOTOR 1
MOTOR 2
LIMIT 1
GND
LIMIT 2
LIMIT 1
LIMIT 2
LIMIT 1
LIMIT 2
OPEN
ON/OFF
BATTERY
CLOSE
PULL
OPEN
A
TE
OFF 2.5 sec
1.5 sec
ARM CONTROLLER
UL SENSOR 10K UL SENSOR N.C.
MOTOR 1
INPUTS
[
+
]
[
-
]
[
+
]
[
-
]
MOTOR 2
INPUTS
R
OLS
O
LLER
DO NOT CYCLE OPERATOR
AT THIS TIME.
DAMAGE COULD OCCUR!
NOTE: Operator cable should be in
flexible conduit (not provided).
Motor 2 (Secondary for Bi-Parting gates)
Motor 1 (Single/Primary gate)
White
Yellow
White
Yellow
Red
Black
Green
Red
Black
Green
max Arm wiring or
Max ultra arm wiring