40
MAX Arm/Ultra Arm V1
solar CONTROL box installation
Select proper solar panel
The map and daily cycle rate shown are
approximations based upon the average
solar radiation and the temperature
effects on batteries in the given regions.
Local geography and weather conditions
may require additional solar panels.
USE LOW POWER accessories in order to
minimize power draw. Each additional
accessory draws power affecting the daily
cycle rate.
SWING, ACTUATOR
ACTUATOR
GATE SOLAR CYCLES PER DAY with built-in 18A/Hr battery
ZONE 1
(6 Hrs Sunlight/Day)
ZONE 2
(4 Hrs Sunlight/Day)
ZONE 3
(2 Hrs Sunlight/Day)
PANEL SIZE
Total System
Current
Draw (mA)
Cycles/day
w/1
rainy day
Cycles/day
w/10
rainy days
Cycles/day
w/1
rainy day
Cycles/day
w/10
rainy days
Cycles/day
w/1
rainy day
Cycles/day
w/10
rainy days
60 W
26 1328 346 1233 252 1138 157
50 1295 314 1197 215 1098 117
100 1227 245 1121 139 1015 33
200 1091 109 970 -12 848 -133
250 1023 41 894 -88 765 -217
85 W
26 1442 460 1309 327 1176 195
50 1409 427 1273 291 1136 155
100 1341 359 1197 215 1053 71
200 1205 223 1045 64 886 -95
250 1136 155 970 -12 803 -179
120 W
26 1601 619 1415 433 1229 248
50 1568 586 1379 397 1189 208
100 1500 518 1303 321 1106 124
200 1364 382 1152 170 939 -42
250 1295 314 1076 94 856 -126
200 W
26 1965 983 1658 676 1351 369
50 1932 950 1621 639 1311 329
100 1864 882 1545 564 1227 245
200 1727 745 1394 412 1061 79
250 1659 677 1318 336 977 -5
Rev. 09/23/19