19
TM
MAINTENANCE
GENERAL MAINTENANCE
Regular and periodic maintenance of the compressor ensures trouble-free operation.
The compressor components should be inspected on a regular basis.
WARNING!
• Potential hazard that could result in serious injury or loss of life.
• To avoid personal injury, always shut off and unplug the
compressor from the power supply outlet and relieve all air
pressure from the air supply system before performing any
service on the air compressor.
• Do not use damaged tool. If abnormal noise or vibration occurs,
rectify the problem before use.
NOTE: During cold temperatures, drain the air tank after each use to
reduce freezing problems.
DRAINING THE AIR TANK
1. Turn OFF the power supply to the pump. Release air pressure in tank by pulling the
relief valve ring.
2. Turn the drain valve counter-clockwise to open it and tilt the tank to drain out water
completely.
DESCRIPTION COMPONENTS Daily Weekly Monthly
Drain moisture Air tank X
Check proper operation Pressure relief valve, air filter X X
Check air leaks, abnormal
noise, or vibration
Worn or broken parts X X
MAXIMUM SERVICE INTERVAL