14
02
AC input voltage range
Appliances (default)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
UPS
If selected, acceptable AC input
voltage range will be within
170-280VAC.
03
Output voltage
220Vac
230V (Default)
240Vac
04
Output frequency
50Hz (default)
60Hz
05
Solar supply priority
Power to charge
battery first (default)
Solar energy provides power to
charge battery as first priority.
Power to the loads
first
Solar energy provides power to the
loads as first priority.
06
Overload bypass:
When enabled, the unit will
transfer to line mode if
overload occurs in battery
mode.
Bypass disable
(default)
Bypass enable
07
Auto restart when overload
occurs
Restart disable
(default)
Restart enable
08
Auto restart when over
temperature occurs
Restart disable
(default)
Restart enable