EasyManua.ls Logo

MaxPower SUNBRIDGE PV6000 - Page 21

Default Icon
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
00:00 to 23:00, increment of each click is 1 hour.
34
Set country customized
regulations
India(Default)
If selected, acceptable feed-in grid
voltage range will be
195.5~253VAC. Acceptable feed-in
grid frequency range will be
49~51Hz.
Germany
If selected, acceptable feed-in grid
voltage range will be
184~264.5VAC. Acceptable feed-in
grid frequency range will be
47.5~51.5Hz.
South America
If selected, acceptable feed-in grid
voltage range will be
184~264.5VAC. Acceptable feed-in
grid frequency range will be
57~62Hz.
95
Time setting Minute
For minute setting, the range is from 00 to 59.
96
Time setting Hour
For hour setting, the range is from 00 to 23.
97
Time setting Day
For day setting, the range is from 00 to 31.
98
Time setting Month
For month setting, the range is from 01 to 12.
99
Time setting Year
For year setting, the range is from 16 to 99.

Related product manuals