Maxwell 25602 - Specifications; Measuring Ranges and Accuracy

Maxwell 25602
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual
EN
specifications
Measuring Ranges and Accuracy
DC Current 0.01A - 1000A
AC Current 0.01A - 1000A
DC Voltage 0.1mV - 1000V
AC Voltage 1mV - 750V
Resistance 0.1Ω - 40MΩ
Capacity 1pF – 100uF
Frequency 0,001Hz-100KHz
Conductor Size 80mm opened
Diode test Opening voltage 0.3mA, voltage 1.5V DC
Continuity Limit value <50Ω; current intensity max.<1mA
Low battery power is shown on the display
Low battery power „OL is shown on the display
Sample Rate 2/mp
Inward impedance 10MΩ (VDC és VAC)
Display 4 digites LCD
AC Current 50-60 Hz (AAC)
AC Voltage 40-400 Hz (VAC)
Operating Temperature -10°C-50°C (14°F-122°F)
Storage temperature -30°C-60°C (-22°F-140°F)
Relative Humidity max. 85%
Standard Cat III. cat. 600V
Battery DC 9V IEC 6F22.1604.
Automatically powered down After about 20 min.
Dimensions 258 x 83 x 45 mm
Súly 425 g (with battery)
DC CURRENT
Range Resolution Accuracy (%)
40A 0.01A ± (3.0% + 8 digit)
400A 0.1A ± (2.5% + 8 digit)
1000A 1A ± (3.0% + 10 digit)

Related product manuals