Control Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
16027233 June 2006
Replaces 16027002
© 2006 Maytag Services
6
Feature Test Procedure Results
H1 Control Panel Assembly Matrix
(MER5875RC*)
Convect
Bake
Oven
Ligh t
Cook &
Ho ld
Keep
Warm
Broil
Bake
Clean
Convect
Roas t
Clock
CANCEL
Timer
Favorite
Delay
Auto set
Continuity is indicated as follows:
1000 – 6600 Ω for Cancel pad.
1000 – 15000 Ω for All other pads.
1
16
9
8
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Clock
Cook & Hold
Broil
Bake
Convect Bake
Convect Roast
Clean
Keep Warm
Favorites
Timer
Light
Trace
13 & 15
12 & 13
12 & 15
4 & 14
4 & 12
4 & 10
5 & 13
5 & 12
5 & 10
10 & 12
1 & 2 or 1 & 3
4 & 5
4 & 7
5 & 7
10 & 11
4 & 13
7 & 14
7 & 15
11 & 12
13 & 14
5 & 14
7 & 13
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
H1 Control: Relay Logic
COOKING MODE
BAKE
BROIL
CONVECT ELEMENT
CONVECT FAN
OVEN LIGHT
IDLE
r r r r
BAKE PREHEAT
z r
r r
BAKE
z r
r r
BROIL PREHEAT
r
z
r r
BROIL
r
z
r r
CLEAN PREHEAT
z z
r r
r
CLEAN
z r
r r
r
KEEP WARM
z
r r r
CONVECT BAKE PREHEAT
z r z z
CONVECT BAKE
z r z z
KEY INDEX
± - OFF
z - ON
- ON OR OFF (DETERMINED BY USER INPUT)
! - TEMPERATURE CONTROLLED