Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless
testing requires power.
September 2006 16026881
©2006 Maytag Services RPL 16026540
5
85¡C ,25A
thermal cut-off
Code Description Trigger Action Taken
8
Stuck Key A key is
sensed to be
pressed
more than
75 seconds,
the key shall
be assumed
to be stuck.
Run membrane pad
check and replace
console w/membrane
pad if necessary.
10
No Wet Clothes
Sensor
bar
detects no
wet
clothes
while a
Sensor
Dry
Cycle
Check for:
- Running dryer
with
no wet clothes in
sensor dry cycle
Display Fault/Error Codes
Display
Description
Trigger
Action
Taken
tS
Dryer
Thermistor
Short
Sensed
The
Thermistor
resistance is
very low.
Check for:
- Clogged
lint
screen.
- Restricted
vent
system.
- Check
Thermistor
resistance.
- Check for
diagnostic
code 1
do
Door Open
Running the
dryer with
door open
Check for:
- Close the
door,
and run the
dryer
- Loose or
open
wire
terminals in
Door Sense
circuit.
- Check for
diagnostic
code 3
FE
Power
source
frequency
Error
Invalid
power
source
frequency
Check for:
- Not using
regular
power
source
frequency
- Invalid
power
frequency
sense
circuit
dC
Door Circuit
Failure
Invalid state
for more
than
256
milliseconds
Check for:
- Loose or
open
wire
terminals in
Door Sense
circuit.
- Check for
diagnostic
code 3
hE
Heater Error
Invalid
heating
termperature
in running
the
dryer
Check for:
- Restricted
vent
system.
- Check
Thermistor
resistance.
Component Electrical Testing
• Thermistor resistance 10K Ω @ 25°C 77°F
(2P-Blue & Red wire)
• Thermostat 1 resistance < 1Ω (White & Yellow wire)
• Thermostat 3 resistance < 1Ω (Red & Black wire)
-If resistance is infinity, replace thermostat 3.
• Thermostat 2 resistance < 1Ω (Blue & Black wire)
-If resistance is infinity, replace thermostat 2.
• Heater resistance 10 Ω (Blue & Blue wire)
-If resistance is infinity, replace Heater.