HAZARD WARNING SWITCH
HAZARD WARNING SWITCH INSPECTION
1. Remove the console.(See CONSOLE REMOVAL/INSTALLATION .)
2. Remove the lower panel.(See LOWER PANEL REMOVAL/INSTALLATION .)
3. Remove the center panel module.(See CENTER PANEL MODULE REMOVAL/INSTALLATION .)
4. Verify that the continuity between the hazard switch terminals is as indicated in the table.
• If not as indicated in the table, replace the center panel.