Attach the chassis ground, +12V and remote wire.
It is important to make sure these connections are
very secure.
Bare metal
Connect the RCA cables to
the INPUT connectors. The
OUTPUT can be used to
provide input for a second
DPSOL¿HU
The chassis ground connection
is critical to the performance
RIWKHDPSOL¿HU&KRRVHD
location that is close to the
DPSOL¿HU&RPSOHWHO\VFUDSH
away the paint and use a nut
and bolt if possible.
DO NOT USE AN EXISTING
FACTORY BOLT!
Power
Connection
Signal Input
Connection
Chassis Ground
5
6
4
Turn the GAIN control completely
counter-clockwise to minimum.
Gain Control
7
Ground - Black
Remote - Blue
+12V - Red
GAIN
MIN MAX