Do you have a question about the McQuay M4MC125D and is the answer not in the manual?
| Brand | McQuay |
|---|---|
| Model | M4MC125D |
| Category | Air Conditioner |
| Language | English |
Indoor unit uses metal blower; outdoor unit uses 6-blade aluminum propeller fan with Class F motor.
High efficiency, refrigerant-cooled Scroll compressors with overload protection and crankcase heater.
Outdoor units feature auto reset high/low pressure cut-outs and phase protector.
Cooling capacity performance data for MDB075D and MMC075D models.
Cooling capacity performance data for MDB100D and MMC100D models.
Cooling capacity performance data for MDB125D and MMC125D models.
Cooling capacity performance data for MDB150D2 and MMC075D x 2 models.
Cooling capacity performance data for MDB200D2 and MMC100D x 2 models.
Cooling capacity performance data for MDB250D2 and MMC125D x 2 models.
Cooling capacity performance data for MDB300D2 and MMC150D x 2 models.
Cooling capacity performance data for MDB400D4 and MMC100D x 4 models.
Cooling capacity performance data for MDB500D4 and MMC125D x 4 models.
Heating capacity data for MDB075DR and MMC075DR models.
Heating capacity data for MDB100DR and MMC100DR models.
Heating capacity data for MDB125DR and MMC125DR models.
Heating capacity data for MDB150DR and MMC150DR models.
Heating capacity data for MDB150DR2 and MMC075DR x 2 models.
Heating capacity data for MDB200DR2 and MMC100DR x 2 models.
Heating capacity data for MDB250DR2 and MMC125DR x 2 models.
Heating capacity data for MDB300DR2 and MMC150DR x 2 models.
Cooling capacity data for MDB075DR and M4MC075DR models.
Cooling capacity data for MDB100DR and M4MC100DR models.
Cooling capacity data for MDB125DR and M4MC125DR models.
Cooling capacity data for MDB150DR2 and M4MC075DR x 2 models.
Cooling capacity data for MDB200DR2 and M4MC100DR x 2 models.
Cooling capacity data for MDB250DR2 and M4MC125DR x 2 models.
Cooling capacity data for MDB300DR2 and M4MC150DR x 2 models.
Cooling capacity data for MDB400DR4 and M4MC100DR x 4 models.
Cooling capacity data for MDB500DR4 and MMC125DR x 4 models.
Performance curve for MDB 075D blower.
Performance curve for MDB 100D blower.
Performance curve for MDB 125D blower.
Performance curve for MDB 150D blower.
Performance curve for MDB 200D blower.
Performance curve for MDB 250D blower.
Performance curve for MDB 300D blower.
Performance curve for MDB 400D blower.
Performance curve for MDB 500D blower.
Performance curve for MDB 075D/DR VERY HIGH STATIC blower.
Performance curve for MDB 100D/DR VERY HIGH STATIC blower.
Performance curve for MDB 125D/DR VERY HIGH STATIC blower.
Precautions for field charging, especially regarding compressor lubrication and temperature.
Precautionary measures for R407C handling, including filter-dryer installation and avoiding moist air.
Guidance on cleaning the outdoor unit heat exchanger for optimal performance.
Wiring regulations and precautions for proper electrical connections.
List and explanation of error codes displayed on the LCD panel.
Flowchart for diagnosing and resolving 'No Cooling' issues.
Flowchart for diagnosing and resolving 'Insufficient Cooling' problems.
Troubleshooting steps for issues related to high discharge pressure.
Troubleshooting steps for issues related to low discharge pressure.
Diagnosing and fixing causes of noisy operation in the unit.