1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151: 1994(E)
3) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB OUTDOOR
Abbreviation :
EXT. O.L.P - External Overload Protector
11
R410A Models
(Cooling only)
INDOOR UNIT
M5WM 007G M5WM 009G M5WM 010G M5WM 015G
OUTDOOR UNIT M5LC 007C M5LC 010C M5LC 010C M5LC 015C
W 2200 2640 2780 3520
Btu/h 7500 9000 9500 12000
INPUT POWER W (50 Hz) 620 865 867 1230
RUNNING CURRENT A (50Hz)
2.93.9 3.95.5
POWER SOURCE V/Ph/Hz
REFRIGERANT / CONTROL
FAN TYPE
AIR FLOW cfm / L/s
300 / 142 345 / 163
FAN MOTOR 50 Hz
4 POLES X 9W 4 POLES X 13W
RATED INPUT POWER W (50 Hz)
26 29
RATED RUNNING CURRENT A (50 Hz) 0.11 0.13
FAN MOTOR PROTECTION
MATERIAL
TUBE PATTERN
DIAMETER mm/in
THICKNESS mm/in
MATERIAL
THICKNESS mm/in
ROW
FIN PER INCH
FACE AREA
m
2
ft
2
HEIGHT mm/in
DIMENSION WIDTH mm/in
DEPTH mm/in
WEIGHT kg/lb
SOUND PRESSURE LEVEL- H / M / L dBA
39 / 34 / 28 42 / 36 / 29
ROOM TEMPERATURE
AIR DISCHARGE
OPERATION
CONDENSATE DRAIN SIZE mm/in
AIR FILTER
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
POWER SOURCE V/Ph/Hz
COMPRESSOR TYPE
CAPACITOR µF
15 25 25 30
RATED RUNNING CURRENT A
2.6 3.6 3.6 5.1
RATED INPUT POWER W 556 789 789 1142
LOCKED ROTOR AMP. A 12 19 19 24
PROTECTION DEVICE EXT. O.L.P EXT. O.L.P EXT. O.L.P EXT. O.L.P
FAN TYPE / DRIVE
BLADE MATERIAL
DIAMETER mm/in
356/14
RATED RUNNING CURRENT A (50 Hz) 0.18 0.23 0.23 0.26
MOTOR OUTPUT
W (50 Hz)
20 35 35 35
RATED INPUT POWER W(50 Hz) 40 52 52 59
MATERIAL
TUBE PATTERN
DIAMETER mm/in
THICKNESS mm/in
MATERIAL
THICKNESS mm/in
ROW
FIN PER INCH
FACE AREA
m
2
ft
2
0.31/3.40
HEIGHT mm/in
495/19.5
DIMENSION WIDTH mm/in
600/23.6
DEPTH mm/in
245/9.7
WEIGHT kg/lb 26/57.32 33/72.75 33/72.75 35/77.16
MATERIAL
CASING THICKNESS mm
FINISHING
SOUND PRESSURE LEVEL
dBA
44 46 46 49
TYPE
LIQUID mm/in
GAS mm/in 12.70 / 1/2
HEIGHT mm/in 575/22.6
WIDTH mm/in 715/28.1
DEPTH mm/in 330/13.0
REFRIGERANT CHARGE kg/lb
0.6/1.32 0.69/1.52 0.69/1.52 0.8/1.76
PACKING
DIMENSION
620/24.4
810/31.9
330/13.0
EG/GI
0.5~2.0
EPOXY POLYESTER POWDER
PIPE
FLARE VALVE
SIZE
6.35 / 1/4
9.52 / 3/8
0.36/3.94
540/21.3
700/27.6
250/9.8
FIN
ALUMINIUM (SLIT FIN)
0.11/0.004
1
18
SEAMLESS COPPER TUBE
INNER GROOVED
9.52 / 3/8
0.372 / 0.015
OUTDOOR UNIT
220-240/1/50
COMPRESSOR
ROTARY HERMETIC
FAN
PROPELLER / DIRECT
GLASS REINFORCED ACRYL STYRENE RESIN
404/16
COIL
TUBE
16 / 0.63
SARANET+IONIZER+DEODORIZER
PACKING
DIMENSION
337 / 13.3 337 / 13.3
857 / 33.7 957 / 37.7
270 / 10.6 270 / 10.6
40 / 35 / 29
CONTROL
THERMOSTAT ELECTRONIC CONTROL
DOUBLE LOUVER (UP & DOWN) & GRILLE (LEFT & RIGHT)
LCD REMOTE CONTROL
198 / 7.8
198 / 7.8
10 / 22.05 12/26.46
260 / 10.2
260 / 10.2
799 / 31.5
899 / 35.4
0.11 / 0.0043
2
18
0.201 / 2.161 0.234 / 2.516
0.11
THERMAL OVERLOAD RELAY
COIL
TUBE
SEAMLESS COPPER TUBE
INNER GROOVED
7.0 / 0.276
0.28 / 0.011
FIN
ALUMINIUM (HYDROPHILIC SLIT FIN TYPE)
MODEL
NOMINAL COOLING CAPACITY
INDOOR UNIT
220-240/1/50
R410A / CAPILLARY TUBE IN OUTDOOR
FAN
ANTI FUNGUS SKEW FAN
275 / 130
4 POLES X 8W
24