1 Safety Precaution
Please take note of the safety item as followings before and after installation process:
1
1 Preparation before Installation
To check the electrical power supply condition, electrical power supply shall meet the requirement of local concerned rule and regulation;
The tolerance of voltage shall be less than ±10% based on the nominal voltage, It is not allowed to share the same power cable for
welding, which will cause the vibration of power supply;
To install the equipment , it is a must to have professional technician or Engineer to conduct the installation, otherwise, If installation is
completely improperly, will cause units leakage of water, electric power and cause fire accident etc;
Please follow up the installation instruction of this manual to avoid any leakage of water, electric power and cause fire
To set up an independent electrical power supply cable and meet the local concerned rule and regulation;
Before installation of outdoor units, it shall build a solid base in the ground, also to take some measure to prevent the typhoon, earthquake
etc;
The floor or base for installation of units shall be strong enough to support the weight of outdoor units; If intensity is not enough will cause
unnecessary damage of units and loss;
To prepare the installation kits and protection kits , such as glove, uniform to avoid any kind of injury;
1
2 Safety Notice on processing of installation
Do not touch the fins of heat exchanger; Improper installation will cause body injury and fins damage to cause low heat exchange
efficiency;
Do fix the outdoor unit tightly, to avoid any vibration; The cover panel of controller box shall be fixed tightly to avoid any dirt, water to enter
to cause some failure and damage;
When installing the indoors units, please be sure the use the air filter and electrical heater provided by the supplier;
When installing the units, in case the leakage of refrigerant, please open the window and door for good ventilation; to avoid any fire
because of the poisonous gas may occurred;
If the indoor unit is installed in a confined limited space, it shall take prevent measure to avoid leakage of refrigerant;
Cable of electrical power shall be far away from water, humidity, to avoid leakage of power and fire accidence;
Do not change any protector setting, otherwise it will cause units failure , fire or explosion;
Do not use the addition to check leakage of refrigerant;
Please do not pull the cable of electrical power too tight, otherwise it will cause the breakage of cable;
To ensure the cable can support sufficient ampere and power consumption;
Units earthling is a must, to avoid any leakage of electrical power ; do not to connect earth line with telephone line;
Indoor condensing water shall be drainage in proper way, to avoid dripping of condensing water, it shall have the insulation material to
wrap the outside layer of piping;
Products shall be handled and carried very carefully, to find the profession people and right equipment for package and transportation of
units;
After proper installation, it shall check the air tightness, to make sure no leakage of piping;
1
3 Notice of test operation
Before running the units, it shall to start the main switch for 12 hours, if not do in this way, it will cause the damage of components; The
power shall be in standby condition if units are required to operation frequently;
Do not to contact the main power switch if the hand is wet to avoid leakage of electrical power;
Do not to remove the front panel or protection guard when units is on operation; the high speed running part of the operation units will
cause unnecessary damage and injury;
Do not the touch the refrigerant piping when units is running or just stop running, to avoid unnecessary hurt for hand because the piping
maybe too hot or too cold;
Do not switch off the power when units stop running, wait for 5 minutes to shut off the electrical power;
Warning
For safety and proper installation of the units, please read this manual carefully before installation
!