Introduction
The LED power supply is a dedicated LED driving device that delivers a constant current/voltage or generates an
adjustable current controlled byanexternaldimmer to LEDs. Depending on its types or design concept, some of
them not only have PFC capability but also can be located in a harsh environment
such as dusty, humid places.
MeanWell’sLEDpowersuppliesincludemetalcase,plasticcase,andPCBtypes.
Installation
1Beforecommencinganyinstallationormaintenancework,pleasedisconnectthepowersupplyfromtheutility.
Ensurethatitcannotbereconnectedinadvertently!
2Keepproperventilationaroundtheunitanddonotstackanyobjectonit.Alsoa1015cmclearancemustbe
keptwhenthe
adjacentdeviceisaheatsource.
3Mounting orientations other than standard orientation or operate under high ambient temperature may
increase the internal component temperature and will require a derating in output current. Pleaserefer to
thespecificationsheettoreceivetheoptimummountingpositionandinformationaboutthe
deratingcurve.
4Currentrating of an approvedprimar y /secondary cable should be greaterthanor equal to that of the unit.
Pleaserefertoitsspecification.
5ForLEDpowersupplieswithwaterproofconnectors,verifythatthelinkagebetweentheunitandthelighting
fixtureistightsothatwatercannotintrudeintothesystem.
6FordimmableLEDpowersupplies,makesurethatyourdimmingcontrolleriscapableofdriving
theseunits.ForELNseries,either“D”or“P”type, require 40mA each unit;for those with“3in 1” dimming
function,e.g.HLGandLPFseries,require0.15mAeachunit.
7Wiring:The
wirecolorwillvarybycountry,pleaserefertothetablebelow.
NorthAmerica EuropeanHarmonized
LiveandACL Black Brown
NeutralandACN white Blue
PEandFG(ClassIonly) Green Green/yellow
aConnecttheFGwire(greenorgreen/yellow)oftheLEDpowersupplytoPE(greenorgreen/yellow),this
stepcanbeskippedwhentheunitismarkedclassII,ungrounded.
bConnecttheACLwire(blackorbrown)oftheLEDpowersupplytoLive(blackorbrown).