LAD Series
Economical Security/Fire Alarm PSU with Battery Charger/UPS
User Manual
+
++
+
Back up-
Charger
Power Supply
LAD 120 240 360 600-/// Series
AC Grid
Load
Battery Pack
UART
RTU
DATA
PROTOCOL
AC
DC
Question and Answer IconNeed help?

Do you have a question about the Mean Well LAD Series and is the answer not in the manual?

Summary

1. Safety Guidelines

2. Introduction

2.1 Model Number Identification

Details the model designation structure for the LAD series power supplies.

2.2 Key Features Overview

Lists the key features and functionalities of the LAD series power supplies.

2.3 Electrical Specifications

LAD-120 Series Electrical Specs

Presents detailed electrical specifications for the LAD-120 series power supplies.

LAD-240 Series Electrical Specs

Details the electrical specifications for the LAD-240 series power supplies.

2.4 Safety Overview and Certifications

2.5 Derating and Static Characteristics

Explains derating curves and static characteristic curves for load and input voltage.

2.6 Mechanical Specifications

Details the mechanical specifications and dimensions of the LAD-120 Series.

3. Installation Introduction

3.1 Installation Requirements and Precautions

Outlines essential requirements and precautions for installing the LAD series power supplies.

3.2 Case Mounting Torque Recommendations

Provides recommended torque values for case mounting screws for LAD series.

3.3 Wiring and Terminal Block Use

3.4 Step-by-Step Installation Guide

Provides step-by-step instructions for installing the LAD series power supply.

3.5 Battery Series and Parallel Connection

Explains how to connect batteries in series and parallel configurations.

4. User Interface Panel

4.1 Panel Description and Indicators

Describes the layout and function of the user interface panel on the LAD series.

4.2 Connector Pin Assignments

Details the pin assignments for the CN2 connector for LAD-360/600xU models.

5. Function Description

5.1 DC-UPS Functionality

Explains the DC-UPS functionality, including how the LAD switches to battery backup.

5.2 UART Communication Functions (U Version)

Details the UART communication capabilities for the 'U version' models.

5.2.1 Forced Start & Remote UPS Control (U Version)

Describes the forced start and remote UPS control functions for 'U version' models.

5.2.3 Buzzer Mode Selection

Explains how to select buzzer modes for fire alarm and evacuation systems.

5.2.4 Battery Inspection via UART

Describes how to read battery voltage via UART and alarm conditions.

5.3 TTL Function Signals (Blank Version)

Details TTL signals for status detection, including AC status and battery status.

5.3.1 AC OK TTL Signal for AC Status

Details the TTL signal for detecting AC status and its behavior under abnormal input.

5.3.2 Battery Connection TTL Signal

Explains the TTL signal for detecting battery connection and reverse polarity.

5.3.3 Battery Low TTL Detection

Describes the TTL signal for battery low detection and undervoltage protection points.

5.3.4 Battery Full TTL Detection

Details the TTL signal for detecting when the battery is fully charged.

5.3.5 Discharge Detection TTL Signal

Explains the TTL signal for detecting discharge status, indicating power source.

5.3.6 Forced Start UPS Mode TTL Signal

Describes the TTL signal for forcing the UPS mode on the LAD series.

5.4 Communication Monitoring Function

Details communication monitoring capabilities via UART for LAD series.

5.4.1 UART Communication Protocol

Details the UART communication protocol for setting, reading, and monitoring LAD series.

5.4.1.1 UART Specification Details

Outlines the UART communication protocol specifications, including baud rate and data format.

5.4.1.2 Communication Timing Parameters

Specifies the timing parameters for UART communication between controller and LAD.

5.4.1.3 Basic UART Packet Structure

Defines the packet structure for UART communication, including R/W byte, data length, and CRC-8.

5.4.1.4 Data Type Definitions

Defines the data types used in the UART communication patterns.

5.4.1.5 Scratchpad Address Data Description

Provides descriptions of data addresses and narrations for controller/PC to LAD communication.

5.4.1.6 Data Transmission Instructions

Explains how data is transferred in packets to reduce processing time.

5.4.1.7 LAD_STATUS Definition

Details the LAD_STATUS, comprising LAD_STATUS_H and LAD_STATUS_L, for status reporting.

5.4.2 Main Electrical Voltage Reading

Provides an example of reading the main electrical voltage via UART.

5.4.2.3 Load Current Reading Example

Shows an example request to read the load current of the LAD series.

5.4.2.4 Battery Voltage Reading Example

Provides an example of reading the battery voltage connected to the LAD-360DU.

5.4.2.5 Single Cell Battery Voltage Reading

Shows how to read the voltage of individual battery cells connected to the LAD-360DU.

5.4.2.6 Battery Undervoltage Protection Point Reading

Explains how to read the battery undervoltage protection point settings.

5.4.2.7 Backup Removal Control Command

Describes the command to disable the backup power supply function.

5.4.2.8 Battery Undervoltage Protection Point Setting

Details the command to set the battery undervoltage protection point.

5.4.2.9 Buzzer Shutdown Control Command

Provides instructions for turning the LAD buzzer on or off.

6. Protections and Failure Correction

6.1 Protections Overview

Details various protection mechanisms implemented in the LAD series power supplies.

6.1.1 Output Overload Protection

Explains the overload protection for the output channels of the LAD series.

6.1.2 Over Temperature Protection

Describes the over-temperature protection mechanism and recovery process.

6.1.3 Output Overvoltage Protection

Details the overvoltage protection for the output and recovery procedure.

6.1.4 Low Battery Voltage Protection

Explains the protection that turns off output when battery voltage is too low.

6.1.5 Battery Reverse Connection Protection

Describes the protection against reverse battery connection.

6.2 Failure Correction Methods

Provides a table of common issues, their possible reasons, and methods for exclusion.

7. Warranty Information

Mean Well LAD Series Specifications

General IconGeneral
BrandMean Well
ModelLAD Series
CategoryPower Supply
LanguageEnglish